First-in-man Trial to Assess the Safety, Performance and Clinical Benefit of the TRICENTO G2 Transcatheter Valve System for Tricuspid Regurgitation

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorMedira GmbH

About this trial

The goal of this clinical trial is to assess if the TRICENTO G2 Transcatheter Valve System for Tricuspid Regurgitation (TRICENTO G2 TVSTR) is safe and efficient in treating severe tricuspid regurgitation in adult patients.

The main questions it aims to answer are:

* Does the treatment with the TRICENTO G2 TVSTR improve symptoms of severe tricuspid regurgitation? * Is the treatment with the TRICENTO G2 TVSTR safe?

Participants will:

* Undergo a minimally invasive procedure for the implantation of the TRICENTO G2 Bioprosthesis using the TRICENTO G2 Delivery System * Visit the clinic for a baseline visit, the procedure itself, 30 days, 3 months, 6 months and 1 year after the procedure

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients with symptomatic tricuspid regurgitation (TR), graded as severe or greater (accord. to TR 5-Tier Grading System TVARC)

Patients with TR leading to NYHA class II, III or IV or clinical signs of right heart failure

Patients suitable for implantation of the TRICENTO G2 Bioprosthesis according to anatomical and clinical criteria assessed by computed tomography, echocardiography and/or right heart catheterization (confirmed by a heart team)

Patients receiving optimal medical treatment for underlying diseases

Disqualifiers

Superior vena cava diameter < 22.9 mm or > 37.1 mm (perimeter derived)

Inferior vena cava diameter < 27.9 mm or > 42.9 mm (perimeter derived)

Right atrium cavity height < 55 mm or > 80 mm (direct path between caval ostia)

Peak right atrial pressure > 50 mmHg

Trial design

Design model

Single group

Treatments tested in this trial

  • TRICENTOG2 Transcatheter Valve System for Tricuspid Regurgitation (TRICENTOG2 TVSTR)

    Device

    The TRICENTO G2 TVSTR consists of a Bioprosthesis and a Delivery System including a Loading Funnel. The Bioprosthesis is an endovascular graft-like implant in combination with a lateral valve element. It is placed into the right atrium while spanning from inferior to superior vena cava leaving the native valve apparatus untouched (heterotopic approach). The TRICENTO G2 Bioprosthesis is designed to reduce the reflux of blood into the caval system during systole while allowing for forward flow during diastole. The TRICENTO G2 Bioprosthesis is delivered minimally invasive by transfemoral venous access using a catheter-based Delivery System.

Treatment groups

10 Participants
are divided into 1 treatment group
Group A: Investigational device (TRICENTO G2 TVSTR)Experimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Technical success: Percentage of participants with successful access, delivery and retrieval of the TRICENTO G2 Delivery System AND successful deployment and correct positioning of the TRICENTO G2 Bioprosthesis measured via echocardiography

Technical success \[given as percentage of participants\] 1. Successful access, tracking and withdrawal of the TRICENTO G2 Delivery System \[Yes/No\] 2. Successful deployment and correct positioning of the TRICENTO G2 Bioprosthesis \[Yes/No\]

Time frame
immediately at the end of procedure
2

Frequency and composite of device-related or procedure-related serious adverse events (SAEs)

With SAE classification according to MDR and MDCG 2020-10.

Time frame
during and immediately after the procedure, at discharge (latest 7 days post-implantation), 30 days post-implantation
3

Frequency of device deficiencies

Device deficiency: Inadequacy of a medical device with respect to its identity, quality, durability, reliability, usability, safety or performance.

Time frame
during and immediately after the procedure, at discharge (latest 7 days post-implantation), 30 days post-implantation
4

Rate of unplanned surgery or re-intervention due to a life-threatening device or procedure failure

Time frame
during and immediately after the procedure, at discharge (latest 7 days post-implantation), 30 days post-implantation

Secondary outcomes

1

Clinical performance and functionality of the TRICENTO G2 Bioprothesis assessed via echocardiography

Assessment via echocardiography (TEE/TTE): * Fully functional bioprosthetic valve demonstrating unrestricted inflow in diastole and no backflow in systole beyond the closing volume * Exclusion of para-prosthetic leakage * Changes in hepatic vein systolic backflow

Time frame
immediately at the end of the procedure, at discharge (latest 7 days post-implantation), 30 days, 3 months, 6 months, 12 months post-implantation
2

Clinical performance and functionality of the TRICENTO G2 Bioprothesis assessed via right heart catheterization

Change in peak central venous pressure (CVP \[mmHg\]) or CVP pulsatility or differential pressure \[mmHg\] over the prosthetic valve right atrium-central venous system.

Time frame
immediately at the end of the procedure, 6 months post-implantation
3

Clinical performance and functionality: Assessment of device position

Assessment of device position assessed via computed tomography (CT).

Time frame
6 months post-implantation
4

Clinical performance and functionality: Assessment of stent geometry

Assessment of stent geometry assessed via computed tomography (CT).

Time frame
6 months post-implantation

Other outcomes

1

Exploartory safety endpoint: Overall mortality

All deaths occurring during the clinical investigation.

Time frame
at baseline, procedure, discharge (latest 7 days post-implantation), 30 days, 3 months, 6 months, 12 months post-implantation
2

Exploratory performance endpoint: Changes in Tricuspid Regurgitation - Effective Regurgitant Orifice Area (TR EROA)

Imaging of cardiac structures via echocardiography, comparing TR EROA \[mm\^2\] to baseline.

Time frame
at procedure, discharge (latest 7 days post-implantation), after 30 days, 3 moths, 6 months, 12 months post-implantation
3

Exploratory performance endpoint: Changes in TR regurgitant volume

Imaging of cardiac structures via echocardiography, comparing TR regurgitant volume \[mL\] to baseline.

Time frame
at procedure, discharge (latest 7 days post-implantation), after 30 days, 3 moths, 6 months, 12 months post-implantation
4

Exploratory performance endpoint: Changes in Tricuspid annular plane systolic excursion (TAPSE)

Imaging of cardiac structures via echocardiography, comparing TAPSE \[mm\] to baseline.

Time frame
at procedure, discharge (latest 7 days post-implantation), after 30 days, 3 moths, 6 months, 12 months post-implantation

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Medira GmbH

Lead sponsor

LS medcap GmbH

Collaborator

Clinical Accelerator

Collaborator