Fluid-responsiveness Assessment Simplified by Electric Cardiometry in Children

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age0-8
SponsorUniversity Hospital, Bordeaux

About this trial

In this study of diagnostic accuracy, the investigators aim to validate a faster, simpler, and noninvasive test of fluid-responsiveness in critically ill children. This test is based on an assessment of the hemodynamic effects of a standardized abdominal compression, using electrical cardiometry. This would help physicians to identify more easily which patient could benefit from a volume expansion, thus avoiding a potentially useless or even dangerous fluid expansion that could lead to fluid overload. To this end, the diagnostic accuracy of electrical cardiometry-based stroke volume (SV) variation induced by a standardized abdominal compression to predict fluid responsiveness (define as a 15% increase in echocardiographically measured SV after volume expansion) will be measured.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age less than or equal to 8 years old

Hospitalization in a pediatric intensive care unit

Prescription by the attending physician of a fluid expansion of 10ml/kg

Use of a non-invasive cardiac output monitoring device (electrical cardiometry) as part of routine care

Disqualifiers

Patient less than 37 weeks' corrected gestational age

Hemodynamic instability making the delay necessary for any test dangerous

Supine position contraindicated or deleterious

Impairment of echocardiographic acoustic window or restless patient making ultrasonography impossible

Trial population

patient hospitalised in intensive care or in a continuous monitoring unit

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • validation a test of fluid-responsiveness in critically ill children

    Diagnostic test

    This test is based on an assessment of the hemodynamic effects of a standardized abdominal compression, using electrical cardiometry.

Treatment groups

42 Participants
are divided into 1 treatment group
Group A: Patient in paediatric intensive care unit1 intervention

Trial outcomes

Primary outcomes

1

Area under the ROC curve (AUROC, %) of ΔSV-ACICON to diagnose fluid responsiveness

Description: The primary outcome measure of a diagnostic accuracy study is the discriminative ability of an index test (expressed as an area under the ROC curve) to diagnose a condition (defined by a positive gold-standard reference test). In this study: * The index test is ΔSV-ACICON = difference between stroke volume measured by electrical cardiometry (ml) during a calibrated abdominal compression (30mmHg for 30 seconds) and stroke volume measured by electrical cardiometry at baseline. * The condition is "fluid responsiveness" * The gold-standard reference test to diagnose fluid responsiveness is a stroke volume (SV) increase of at least 15% between baseline and after volume expansion: ΔSV-VE \> 15% = ((SV after volume expansion - SV at baseline) / SV at baseline) \> 15%. SV (ml) will be measured by transthoracic echocardiography as the product of left ventricular outflow tract surface (cm², from a parasternal long axis view) and left ventricular outflow tract velocity-time integral

Time frame
between baseline and 1 hour

Secondary outcomes

1

AUROC (%) of the following index test to diagnose fluid responsiveness (same definition as above )

Respiratory variability of peak aortic velocity at baseline (%)

Time frame
between baseline and 1 hour
2

AUROC (%) of the following index test to diagnose fluid responsiveness (same definition as above )

Respiratory variability of inferior vena cava diameter at baseline (%)

Time frame
between baseline and 1 hour
3

AUROC (%) of the following index test to diagnose fluid responsiveness (same definition as above )

Stroke volume respiratory variations at baseline (%), measured with electrical cardiometry

Time frame
between baseline and 1 hour
4

AUROC (%) of the following index test to diagnose fluid responsiveness (same definition as above )

Abdominal compression induced variations in arterial pressure (%)

Time frame
between baseline and 1 hour