Fluid Responsiveness in Laparoscopic Surgery: End-Expiratory Occlusion Test Versus Mini-Fluid Challenge

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorUniversity Of Perugia

About this trial

Background Fluid management is central to perioperative care, but only about half of surgical patients increase their stroke volume after a fluid challenge. Dynamic indices such as pulse pressure variation and stroke volume variation are often unreliable during laparoscopy, because of low tidal volume ventilation and carbon dioxide (CO2) pneumoperitoneum. Functional hemodynamic tests may overcome these limitations. In the Mini fluid chAllenge aNd End-expiratory occlusion test to assess flUid responsiveness in the opeRating room (MANEUVER) study (NCT03808753), conducted in open abdominal surgery, the mini-fluid challenge predicted fluid responsiveness well, whereas the end-expiratory occlusion test did not. Pneumoperitoneum raises intra-abdominal pressure instead of abolishing it, so these results cannot be extrapolated to laparoscopy.

Design FLUID-LAP is a prospective, multicenter, observational diagnostic-accuracy cohort study conducted in four Italian centers and reported according to the Standards for Reporting of Diagnostic Accuracy (STARD) 2015 statement. Each patient is their own control: both index tests and the reference standard are performed in sequence in the same patient during a period of stable intraoperative hemodynamics, so the resulting receiver operating characteristic (ROC) curves are correlated. The study replicates the design of MANEUVER, changing only the surgical setting. Ventilation (volume-controlled, 7 ml/kg predicted body weight), the reference fluid challenge and uncalibrated pulse-contour monitoring are the same, to allow direct comparison with the open-abdomen data.

Procedures Tests are performed under standardized baseline conditions (stable pneumoperitoneum and position, unchanged ventilation, no recent drug changes or surgical manipulation, arterial waveform checked with a square-wave test). The order of the two index tests is chosen by the attending anesthesiologist, is recorded for every patient, and is analyzed as a pre-specified covariate. A 3-minute return to steady state separates the tests. The complete 4 ml/kg fluid challenge is given after both tests. The maneuvers are already part of routine goal-directed practice, and no treatment decision is dictated by the protocol. Patient safety always prevails over the protocol.

Analysis The primary analysis compares the areas under the ROC curves (AUC) of the two tests using the DeLong test. The expected AUCs are 0.90 for the mini-fluid challenge and 0.75 for the end-expiratory occlusion test. With 80% power and a two-sided alpha of 0.05, 87 evaluable patients are required; 104 will be enrolled to allow for 15% attrition (26 per center). Pre-specified analyses address the mathematical coupling between the mini-fluid challenge and the reference challenge, the effect of test order, and subgroups by intra-abdominal pressure and patient position.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 years or older

Scheduled for elective major laparoscopic or robot-assisted surgery (abdominal, urological or gynecological-oncological) under CO2 pneumoperitoneum, with expected duration longer than 60 minutes

Controlled mechanical ventilation (volume-controlled, tidal volume 7 ml/kg predicted body weight)

Invasive arterial pressure monitoring and continuous uncalibrated pulse-contour cardiac output monitoring in place as standard of care

Disqualifiers

Any recurrent cardiac arrhythmia

Known reduced left ventricular (ejection fraction below 30%) or right ventricular (tricuspid annular systolic peak velocity below 0.17 m/s) systolic function

Severe valvular heart disease

Body mass index above 35 kg/m2

Trial population

Adults undergoing elective major laparoscopic or robot-assisted abdominal, urological or gynecological-oncological surgery under CO2 pneumoperitoneum, mechanically ventilated, with invasive arterial pressure and uncalibrated pulse-contour cardiac output monitoring, recruited at four centres.

Trial design

Design model

Case-control

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

104 Participants
are grouped into 1 trial group
Group A: Adults undergoing major laparoscopic or robot-assisted surgery

Trial outcomes

Primary outcomes

1

Difference in area under the ROC curve (AUC) between the mini-fluid challenge and the end-expiratory occlusion test for predicting fluid responsiveness

Percent change in stroke volume index (ΔSVI%) after the mini-fluid challenge (100 ml lactated Ringer's over 1 minute) and after the end-expiratory occlusion test (30-second expiratory hold) is used as a continuous predictor. Fluid responsiveness is defined as an increase in stroke volume index of 10% or more after a fluid challenge of 4 ml/kg predicted body weight of lactated Ringer's over about 10 minutes. The AUCs of the two tests are compared as correlated ROC curves using the DeLong test. Stroke volume index is measured by uncalibrated pulse-contour analysis.

Time frame
Perioperative/Periprocedural

Secondary outcomes

1

Area under the ROC curve (AUC) of each test for predicting fluid responsiveness

AUC with 95% confidence interval (DeLong) of the percent change in stroke volume index after the end-expiratory occlusion test (30 seconds) and after the mini-fluid challenge, and of baseline pulse pressure variation (PPV) and stroke volume variation (SVV), for predicting fluid responsiveness (increase in stroke volume index of 10% or more after a 4 ml/kg fluid challenge).

Time frame
Perioperative/Periprocedural
2

Optimal cut-off, sensitivity, specificity, predictive values and likelihood ratios of each test

For the end-expiratory occlusion test and the mini-fluid challenge: best cut-off of the percent change in stroke volume index by the Youden index, with sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios, each with 95% confidence interval (Wilson method).

Time frame
Perioperative/Periprocedural
3

Prevalence of fluid responsiveness in the study population

Proportion of participants with an increase in stroke volume index of 10% or more after the 4 ml/kg fluid challenge of lactated Ringer's over about 10 minutes.

Time frame
Perioperative/Periprocedural
4

Grey zone of each test and comparison of grey-zone widths

Grey zone of the end-expiratory occlusion test and of the mini-fluid challenge, defined by a lower cut-off including 90% of non-responders and an upper cut-off predicting fluid responsiveness in 90% of cases. The intermediate range is considered inconclusive. The widths of the two grey zones are compared.

Time frame
Perioperative/Periprocedural

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: