Focused Ultrasound and Stomach-Brain Activity in Healthy Adults

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-50
SponsorEvan (Huiliang) Wang

About this trial

This study examines whether focused ultrasound applied over the stomach changes stomach and brain electrical activity in healthy adults. Researchers are evaluating an investigational wearable device that combines electrodes for recording stomach electrical activity with a focused ultrasound transducer. The goal is to improve understanding of communication between the stomach and brain.

Each participant completes two study visits, receiving active ultrasound during one visit and sham stimulation during the other. The order is assigned at random. Sham stimulation uses the same device placement without delivering ultrasound. Participants and outcome assessors do not know which condition is being administered.

Each visit includes resting baseline, viewing a virtual reality video, continued viewing during active or sham stimulation, and resting recovery. Sensors record electrical activity from the brain, stomach, and heart. Participants also report nausea and dizziness. No direct medical benefit is expected from participation.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Healthy adults aged 18 to 50 years.

Willing and able to undergo electroencephalography (EEG), electrocardiography (ECG), electrogastrography (EGG), and focused ultrasound (FUS) procedures.

Disqualifiers

Implanted electronic medical devices, such as pacemakers or neurostimulators.

Active skin conditions, such as rashes, open wounds, or severe eczema, on the abdominal area where electrodes will be placed.

Trial design

Design model

Crossover

Treatments tested in this trial

  • Wearable Electrogastrogram and Focused Ultrasound Stimulation Device

    Device

    The wearable ultrasound transducer is positioned over the stomach using acoustic coupling gel. Participants receive active gastric focused ultrasound during the 10-minute combined visual stimulation and intervention block.

  • Sham Gastric Focused Ultrasound

    Device

    The wearable ultrasound transducer is positioned over the stomach using acoustic coupling gel. The device delivers zero ultrasound output during the 10-minute sham intervention block while visual stimulation continues.

  • Visual Motion Stimulation

    Behavioral

    Participants watch an immersive virtual reality video for 10 minutes before active or sham stimulation begins. The same video continues throughout the 10-minute intervention block.

Treatment groups

12 Participants
are divided into 2 treatment groups
Group A: Active Gastric Focused Ultrasound Followed by Sham StimulationExperimental treatment 3 interventions
Group B: Sham Stimulation Followed by Active Gastric Focused UltrasoundExperimental treatment 3 interventions

Trial outcomes

Primary outcomes

1

Change in Electroencephalographic Signal Amplitude Standard Deviation

EEG signals are band-pass filtered at 0.5-40 Hz and cleaned using fixed artifact-rejection rules. Within each 10-minute block, signal-amplitude standard deviation is calculated for each eligible EEG channel, then averaged equally across the same channels at both visits. The measure is reported in microvolts. For each visit, change is the visual-plus-intervention block value minus the preceding visual-only block value. Changes during active and sham stimulation are compared within participants. Reference, ground, and non-EEG channels are excluded.

Time frame
Periprocedural at Visits 1 and 2 (10-minute visual-only block before stimulation and minutes 0-10 of the active or sham stimulation block).
2

Change in Electrogastrographic Signal Amplitude Standard Deviation

EGG signals are band-pass filtered at 0.01-0.25 Hz and cleaned using fixed artifact-rejection rules. Within each 10-minute block, signal-amplitude standard deviation is calculated for each eligible EGG recording channel, then averaged equally across the same channels at both visits. The measure is reported in microvolts. For each visit, change is the visual-plus-intervention block value minus the preceding visual-only block value. Changes during active and sham stimulation are compared within participants.

Time frame
Periprocedural at Visits 1 and 2 (10-minute visual-only block before stimulation and minutes 0-10 of the active or sham stimulation block).

Secondary outcomes

1

Change in Electroencephalographic Alpha Band Power

EEG alpha power is the integral of Welch's power spectral density from 8 to 13 Hz, reported in squared microvolts. Power is calculated separately for each eligible EEG channel and averaged equally across the same channels at both visits. For each visit, change is the visual-plus-intervention block value minus the preceding visual-only block value. Changes during active and sham stimulation are compared within participants.

Time frame
Periprocedural at Visits 1 and 2 (10-minute visual-only block before stimulation and minutes 0-10 of the active or sham stimulation block).
2

Change in Electrogastrographic Slow Wave Band Power

Gastric slow-wave power is the integral of Welch's power spectral density from 0.03 to 0.07 Hz, reported in squared microvolts. Power is calculated separately for each eligible EGG recording channel and averaged equally across the same channels at both visits. For each visit, change is the visual-plus-intervention block value minus the preceding visual-only block value. Changes during active and sham stimulation are compared within participants.

Time frame
Periprocedural at Visits 1 and 2 (10-minute visual-only block before stimulation and minutes 0-10 of the active or sham stimulation block).
3

Change in Peak Gastric Slow Wave Frequency

For each block, Welch's power spectral density is averaged equally across eligible EGG recording channels. Peak gastric slow-wave frequency is the frequency of maximum spectral density within 0.03-0.07 Hz, reported in hertz. The same channels are used at both visits. For each visit, change is the visual-plus-intervention block value minus the preceding visual-only block value. Changes during active and sham stimulation are compared within participants. This measure does not assess frequency abnormalities outside the specified band.

Time frame
Periprocedural at Visits 1 and 2 (10-minute visual-only block before stimulation and minutes 0-10 of the active or sham stimulation block).
4

Change in Gastric Phase to Electroencephalographic Alpha Amplitude Coupling

Coupling is calculated between the Hilbert phase of EGG activity filtered at 0.03-0.07 Hz and the Hilbert amplitude envelope of EEG activity filtered at 8-13 Hz. The Tort normalized modulation index is calculated using 18 equal phase bins and averaged equally across the same eligible EEG-EGG channel pairs at both visits. The index is unitless and ranges from 0 to 1; larger values indicate stronger phase-dependent modulation, without implying clinical benefit. For each visit, change is the visual-plus-intervention block value minus the preceding visual-only block value. Changes are compared within participants between active and sham stimulation.

Time frame
Periprocedural at Visits 1 and 2 (10-minute visual-only block before stimulation and minutes 0-10 of the active or sham stimulation block).

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Evan (Huiliang) Wang

Lead sponsor

University of Texas at Austin

Sponsor institution