About this trial
This study will evaluate the feasibility, tolerability, and preliminary analgesic effects of individualized Precision Confidence Mapping-guided low-intensity focused ultrasound neuromodulation in adults with chronic pain.
Participants will undergo MRI and resting-state fMRI to identify an individualized SCAN-connected centromedian thalamic target. Participants will then complete two treatment arms in randomized order: focused centromedian thalamic low-intensity focused ultrasound and unfocused control low-intensity focused ultrasound. Each treatment arm includes five consecutive daily stimulation sessions, separated by a washout interval.
The primary outcome is change in daily pain intensity measured using Brief Pain Inventory pain intensity items. Secondary outcomes include pain-related symptoms, physical function, fatigue, sleep disturbance, depressive symptoms, anxiety symptoms, pain catastrophizing, pain vigilance, neuropathic pain features, feasibility, tolerability, adverse events, blinding integrity, and exploratory neuroimaging measures.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older at the time of enrollment
Able to provide written informed consent
Able to read and communicate verbally and in writing in English
Able and willing to comply with all study procedures, including MRI, LIFU sessions, remote REDCap questionnaires, and daily pain diary completion
Disqualifiers
Standard MRI contraindications, including ferromagnetic implants, pacemaker or other non-MRI-compatible implanted devices, cochlear implant, intracranial aneurysm clip, retained metallic foreign body, or other MRI-incompatible device or condition
Inability of the participant's head to fit within the MRI head coil while wearing the MR-compatible device
Inability to tolerate MRI scanning, including severe claustrophobia not manageable with standard non-sedating accommodations
Implanted metallic hardware in the skull, scalp, or temporal bone that would interfere with LIFU targeting or acoustic transmission
Trial design
Crossover
Treatments tested in this trial
Focused PCM-Guided CMN LIFU
DeviceFocused low-intensity focused ultrasound will be delivered using the Attune Neurosciences ATTN201 device to an individualized SCAN-connected centromedian thalamic target identified from resting-state fMRI using Precision Confidence Mapping. Stimulation will be delivered once daily for five consecutive treatment days.
Unfocused Control LIFU
DeviceUnfocused control low-intensity focused ultrasound will use the same device placement, acoustic gel application, pulse timing, session duration, and five-day treatment schedule as focused stimulation. Randomized element delays will be used to produce diffuse acoustic output and negligible focal pressure at the intended deep brain target.
Treatment groups
Trial outcomes
Primary outcomes
Change in Daily Pain Intensity
Daily pain intensity will be measured using the Brief Pain Inventory pain intensity items. The daily pain intensity composite will be calculated as the mean of four 0 to 10 ratings: current pain, worst pain, least pain, and average pain over the past 24 hours. The primary analysis will compare within-participant change in daily pain intensity after focused PCM-guided CMN LIFU versus unfocused control LIFU.
Secondary outcomes
Change in Pain Interference Measured by the Brief Pain Inventory (BPI) Pain Interference Subscale
Pain interference will be measured with the 7-item Pain Interference subscale of the Brief Pain Inventory, covering general activity, mood, walking ability, normal work, relations with other people, sleep, and enjoyment of life over the past week. Each item is rated from 0 (does not interfere) to 10 (completely interferes). The outcome is the mean of the 7 items (range 0-10). Higher scores indicate greater pain interference. Change is calculated as Day 7 minus the pre-arm baseline for each treatment condition.
Change in Physical Function Measured by the PROMIS Physical Function Short Form 6b T-Score
Physical function will be measured with the Patient-Reported Outcomes Measurement Information System (PROMIS) Short Form v2.0 Physical Function 6b, 6 items each scored 1 to 5 (raw score range 6 to 30). Item responses will be converted to a standardized T-score (U.S. general population mean 50, standard deviation 10). Higher scores indicate better physical function (better outcome). Change will be calculated from the pre-arm baseline to Day 7 of the same arm (approximately 2 days after the fifth session) and compared between focused CMN LIFU and unfocused control LIFU.
Change in Fatigue Measured by the PROMIS Fatigue Short Form 13a T-Score
Fatigue will be measured with the Patient-Reported Outcomes Measurement Information System (PROMIS) Short Form v1.0 Fatigue 13a (FACIT-Fatigue), 13 items with a 7-day recall, each scored 1 to 5 (raw score range 13 to 65). Item responses will be converted to a standardized T-score (U.S. general population mean 50, standard deviation 10). Higher scores indicate more fatigue (worse outcome). Change will be calculated from the pre-arm baseline to Day 7 of the same arm (approximately 2 days after the fifth session) and compared between focused CMN LIFU and unfocused control LIFU.
Change in Insomnia Severity Measured by the Insomnia Severity Index (ISI) Total Score
Insomnia severity will be measured with the 7-item Insomnia Severity Index, administered with a 7-day recall period. Each item is rated from 0 to 4, and the total score ranges from 0 to 28. Higher scores indicate more severe insomnia (worse outcome). Change will be calculated from the pre-arm baseline to Day 7 of the same arm (approximately 2 days after the fifth session) and compared between focused CMN LIFU and unfocused control LIFU.
Other outcomes
Distance Between the Individualized PCM-Derived CMN Target and the Atlas-Based CMN Target
Euclidean distance, in millimeters, between each participant\'s individualized SCAN- connected centromedian nucleus (CMN) target identified by Precision Confidence Mapping and the probabilistic atlas-based CMN coordinate, measured in the participant\'s native T1-weighted MRI space.
Resting-State Functional Connectivity Between the CMN Target and Cortical SCAN
Functional connectivity between the individualized CMN target and the participant\'s cortical Somato-Cognitive Action Network (SCAN) regions, computed from baseline resting-state fMRI as the Fisher z-transformed Pearson correlation of their time series (unitless; higher values indicate stronger connectivity).
Minutes of Usable Resting-State fMRI Data After Motion Censoring
Minutes of resting-state fMRI data retained after removing frames with framewise displacement of 0.2 mm or greater.
Correlation Between Baseline CMN-SCAN Functional Connectivity and Pain Response to Focused CMN LIFU
Spearman correlation coefficient (range -1 to 1) between (1) baseline CMN-to-cortical SCAN functional connectivity (Fisher z-transformed Pearson correlation, measured using (1) baseline resting-state fMRI and (2) change in daily Brief Pain Inventory pain intensity (0 to 10 scale; mean of current, worst, least and average pain) from the pre-arm baseline to Days 6 to 7 after the focused CMN LIFU arm, relative to the same change after unfocused control LIFU.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: