About this trial
The surgical management of distal radius fractures via open reduction and internal fixation (ORIF) remains the gold standard for restoring wrist function. However, the procedure is traditionally characterized by repetitive workflow interruptions of the removal of metallic retractors to avoid radiological artifacts and the ergonomic strain of the "head-turn" required to view distant fluoroscopy monitors.
The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries. This device was developed at the University of Hong Kong and invention is held by HKU Versitech Limited.
This study aims to definitively evaluate the gadget-optimized distal radius fixation surgery with the RRRR and head-mounted Augmented Reality glasses display to optimize the surgical workflow. This trial will evaluate whether this system provides a more efficient alternative to conventional monitor-based fluoroscopy in modern orthopedic practice.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Adults (18-85 years)
Distal radial fractures requiring Open Reduction and Internal Fixation.
Patients that would be suitable for the volar approach.
Disqualifiers
Open fractures
Active infection
Polytrauma patients where the wrist is not the primary focus.
Trial design
Parallel
Treatments tested in this trial
Radial Radiolucent Ring Retractor
DeviceThe Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries.
Augmented Reality Glasses
DeviceAugmented Reality of C-Arm intraoperative fluoroscopic imaging integration with a head mount-display (HMD).
Metal Retractor
DeviceManual traditional metal retractor used by surgeons and assistants.
Standard X-ray monitor
DeviceStandard X-ray monitor that displays fluoroscopy images during the operation.
Treatment groups
Trial outcomes
Primary outcomes
Total Fluoroscopy Time
The total duration, measured in minutes or seconds, that the X-ray beam is actively turned on during a fluoroscopic procedure during the operation.
Functional Assessment measured by QuickDASH Score
The QuickDASH score is a validated, internationally recognized tool to assess functional outcomes of patients of the upper arm, especially in long term recovery assessments. The survey will assess the control group against intervention group in return to daily activities, assessment of overall upper limb function, symptoms, and quality of life.
Secondary outcomes
Rating of placement of implant using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the placement of implant rated by the surgeon.
Rating of ergonomics and visualisation of plate position using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the ergonomics and visualisation of plate position rated by the surgeon.
Rating of retraction during fluoroscopy using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the retraction during fluoroscopy rated by the surgeon.
Rating of fracture reduction using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the quality of fracture reduction rated by the surgeon.