Function-Friendly Semi-Fowler Positioning for Coronary Angiography and PCI

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-75
SponsorShanghai Zhongshan Hospital

About this trial

This study will assess whether planned coronary angiography (CAG), and simple percutaneous coronary intervention (PCI) when needed, can be completed safely and technically while participants are in a semi-sitting position with the head of the procedure table raised to 60 degrees. Ten clinically stable adults scheduled for an elective procedure are planned. The first stage will include participants undergoing CAG. After a safety review, the study may include participants expected to need only simple PCI. Heart rhythm, blood pressure, and blood oxygen will be monitored continuously. If predefined safety criteria occur, staff will lower the table or return the participant to a flat position and provide usual clinical care. Researchers will describe procedure completion, image quality, radiation exposure, contrast use, tolerance of the position, and safety events through 3 days after the procedure. This exploratory study is not designed to establish treatment efficacy.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 to 75 years.

Clinically stable and scheduled for elective coronary angiography (CAG) or planned simple percutaneous coronary intervention (PCI), with no ongoing resting ischemia.

Meets clinical indications for coronary angiography or intervention, with ischemic evidence consistent with coronary artery disease based on symptoms, ECG, or noninvasive imaging.

Planned radial access; the operator expects the procedure can be performed using standard catheters and devices.

Disqualifiers

Pregnant or breastfeeding, or the participant or spouse plans pregnancy within the next 6 months.

Known contraindication to local anesthetic or history of severe contrast-media allergy.

Neurologic or psychiatric disease or language impairment that prevents effective communication or cooperation.

Serious comorbidity with expected survival less than 6 months.

Trial design

Design model

Single group

Treatments tested in this trial

  • Function-Friendly Semi-Fowler Positioning

    Other intervention

    The procedure table head is elevated to a default 60-degree semi-Fowler position during elective transradial coronary angiography and, if clinically indicated, simple PCI. ECG, blood pressure, and oxygen saturation are continuously monitored. If predefined safety criteria occur, the table angle is reduced or the participant is immediately returned to 0-degree supine and usual clinical care is provided. The commercial angiography X-ray system and adjustable procedure table are used as available clinical equipment; no device hardware, software, collision protection, interlocks, image processing, or dose-control functions are modified or evaluated.

Treatment groups

10 Participants
are divided into 1 treatment group
Group A: Function-Friendly Semi-Fowler PositioningExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Proportion of Participants With Coronary Angiography (CAG) Technical Success

The number of participants undergoing CAG who complete the planned CAG in the prespecified semi-Fowler position without position-related unplanned return to supine or substantial angle reduction, procedure discontinuation, access-site change, missing key projections, or participant/equipment collision, and whose images are independently confirmed to be diagnostic, divided by the number of participants undergoing CAG.

Time frame
During the CAG procedure
2

Proportion of Participants With Percutaneous Coronary Intervention (PCI) Technical Success

Among participants who undergo PCI, the proportion who complete planned device delivery, treatment, and withdrawal while meeting the protocol-defined positioning and safety requirements. PCI success is calculated using participants who undergo PCI as the denominator.

Time frame
During the PCI procedure
3

Participants With Position-Related Serious Adverse Events or Prespecified Safety Events

Number and proportion of participants experiencing a position-related serious adverse event or any prespecified safety event: hemodynamic instability, hypoxia, sustained arrhythmia, cerebral hypoperfusion, unplanned respiratory or circulatory support, mechanical collision, or emergency return to supine.

Time frame
From the start of the positioning intervention through 3 days after the procedure

Secondary outcomes

1

Diagnostic Acceptability of Coronary Angiography Images

Coronary angiography and fluoroscopy image quality rated on a 1-to-3 Likert scale; a score of 2 or 3 is acceptable. Images are assessed by two independent physicians, with adjudication by a third if needed.

Time frame
During the procedure
2

Completion of Standard Coronary Angiographic Views and Visualization of Major Coronary Segments

Completion of standard left anterior oblique, right anterior oblique, cranial, and caudal projections, and the ability to visualize the left anterior descending, left circumflex, and right coronary arteries and their major branches.

Time frame
During the procedure
3

Total Fluoroscopy Time

Total fluoroscopy time recorded during the CAG and, if performed, PCI procedure.

Time frame
During the procedure
4

Dose-Area Product (DAP)

Dose-area product and other radiation dose parameters recorded by the angiography system.

Time frame
During the procedure

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: