About this trial
Laparoscopic training involves learning to control surgical instruments while viewing movements on a screen. Feedback can help learners identify technical problems and plan further practice, but providing individualized guidance can require substantial instructor time.
This study compares personalized feedback assisted by generative artificial intelligence (AI) with feedback produced using predefined rules and fixed statements. The purpose is to determine whether AI assistance provides additional benefits for laparoscopic skills learning. The investigators hypothesize that AI-assisted personalized feedback will help medical students improve laparoscopic skills more than structured rule-based feedback.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Age ≥18 years and able to provide written informed consent.
Fourth-year undergraduate medical students enrolled at Shandong University Qilu Second Hospital.
No or limited previous laparoscopic simulation skills training, defined as no systematic completion of Fundamentals of Laparoscopic Surgery (FLS) or equivalent core laparoscopic simulation training reaching proficiency.
Able to complete the scheduled study procedures, including baseline assessment, training sessions, post-training assessments, and follow-up assessment.
Disqualifiers
Previous systematic FLS training or equivalent laparoscopic simulation skills training with established proficiency.
Previous laparoscopic operative experience or simulation experience likely to result in substantial ceiling effects.
Conditions that may substantially affect fine motor skills, visuospatial ability, or safe completion of simulation tasks.
Any other condition considered by investigators to make participation inappropriate or unsafe.
Trial design
Parallel
Treatments tested in this trial
Generative AI-Assisted Personalized Feedback
BehavioralThis intervention consists of generative artificial intelligence-assisted personalized feedback provided during laparoscopic skills training. The feedback is generated through a study-specific AI workflow using de-identified structured training data, including objective task performance measures, error events, technical assessment scores, and self-assessment information. The AI-generated feedback identifies individualized training priorities, provides practice suggestions, and defines observable goals for subsequent training. All AI-generated feedback undergoes predefined quality review before delivery. Participants receive four scheduled feedback events during the training period.
Structured Template-Based Feedback
BehavioralThis intervention consists of structured template-based feedback provided during laparoscopic skills training. Feedback is generated using a predefined rule-based system with fixed criteria, priorities, target conditions, and feedback statements. The template system uses the same categories of structured training data and the same feedback schedule as the generative AI-assisted feedback group. Participants receive four scheduled feedback events during the training period.
Treatment groups
Trial outcomes
Primary outcomes
Fundamentals of Laparoscopic Surgery Precision Cutting-Derived Objective Score (PCOS) at T4
Precision cutting performance will be assessed using the study-defined Precision Cutting Objective Score derived from the Fundamentals of Laparoscopic Surgery task. PCOS = max(0, 300 - T - 100 × Aerror/Atarget), where T is completion time in seconds, Aerror is the exclusive-or area between the target and actual cutting contours, and Atarget is the target area. Scores range from 0 to 300; higher scores indicate better performance. Incomplete tasks or completion times of 300 seconds or longer receive 0. Technically unevaluable assessments are treated as missing. This is a research score, not an official FLS certification score.
Secondary outcomes
Fundamentals of Laparoscopic Surgery Peg Transfer-Derived Objective Score (PTOS) at T2
Peg transfer performance will be assessed using the study-defined Peg Transfer Objective Score derived from the Fundamentals of Laparoscopic Surgery task. PTOS = max(0, 300 - T - 100 × Nlost/6), where T is completion time in seconds and Nlost is the number of irretrievable objects. Scores range from 0 to 300; higher scores indicate better performance. Incomplete tasks or completion times of 300 seconds or longer receive 0. Recoverable drops do not incur an additional direct penalty. Technically unevaluable assessments are treated as missing. This is a research score, not an official FLS certification score.
Transfer Training Task Performance Assessed With the Task-Specific Behaviorally Anchored Rating Scale (TS-BARS)
Learning progression on the 14-ball transfer training task will be assessed using the study-specific Task-Specific Behaviorally Anchored Rating Scale. Seven domains are scored from 0 to 5, yielding a total score of 0-35; higher scores indicate better technical performance. The mean of two independent masked assessors' valid total scores will be used after any required discrepancy review. Repeated total scores will characterize the training trajectory.
Cutting Training Task Performance Assessed With the Task-Specific Behaviorally Anchored Rating Scale (TS-BARS)
Learning progression on the study-developed shape-cutting training task will be assessed using the study-specific Task-Specific Behaviorally Anchored Rating Scale. Seven domains are scored from 0 to 5, yielding a total score of 0-35; higher scores indicate better technical performance. The mean of two independent masked assessors' valid total scores will be used after any required discrepancy review. Repeated total scores will characterize the training trajectory.
Other outcomes
Precision Cutting Skill Retention Assessed With the Precision Cutting Objective Score (PCOS) at T5
Retention will be assessed by repeating the Fundamentals of Laparoscopic Surgery Precision Cutting task and calculating the study-defined Precision Cutting Objective Score: max(0, 300 - completion time in seconds - 100 × error area/target area). Scores range from 0 to 300; higher scores indicate better retained performance. The same completion, time-limit, and evaluability rules used for the T4 assessment will apply.
Peg Transfer Skill Retention Assessed With the Peg Transfer Objective Score (PTOS) at T5
Retention will be assessed by repeating the Fundamentals of Laparoscopic Surgery Peg Transfer task and calculating the study-defined Peg Transfer Objective Score: max(0, 300 - completion time in seconds - 100 × number of irretrievable objects/6). Scores range from 0 to 300; higher scores indicate better retained performance. The same completion, time-limit, and evaluability rules used for the T2 assessment will apply.
Transfer Training Self-Assessment Absolute Calibration Error Relative to TS-BARS Ratings at T2
Self-assessment accuracy will be quantified as the mean absolute difference between the learner's domain-level self-ratings and the corresponding mean ratings from two independent assessors using the Task-Specific Behaviorally Anchored Rating Scale for the transfer training task. Each comparable domain is rated from 0 to 5. Absolute calibration error ranges from 0 to 5; lower values indicate more accurate self-assessment.
Cutting Training Self-Assessment Absolute Calibration Error Relative to TS-BARS Ratings at T4
Self-assessment accuracy will be quantified as the mean absolute difference between the learner's domain-level self-ratings and the corresponding mean ratings from two independent assessors using the Task-Specific Behaviorally Anchored Rating Scale for the cutting training task. Each comparable domain is rated from 0 to 5. Absolute calibration error ranges from 0 to 5; lower values indicate more accurate self-assessment.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Yang Xiaodong
Lead sponsor
The Second Hospital of Shandong University
Sponsor institution