Guo&Amp;'s Distal Entry Tear Repair With WeFlow-EndoPatch System (Gallant Study)

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-80
SponsorHangzhou Endonom Medtech Co., Ltd.

About this trial

A Multicenter, Randomized Controlled Study About the Safety and Efficacy of WeFlow-EndoPatch Aortic Endovascular Patch System manufactured by EndoNom Medtech (Hangzhou) Co., Ltd. for Chronic Aortic Dissection . (GALLANT Study)

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients aged 18 to 80 years old, no gender limitation;

The patient was diagnosed with chronic aortic dissection after the repair of the main artery dissection, with distal tears required seal;

The maximum diameter of the descending thoracic aorta is 3.5-5cm;

The number of thoracic descending aorta tears is ≤2, and the maximum diameter of the tears is 2-30 mm;

Disqualifiers

Rupture or threatened rupture of aortic dissection;

Proximal type I internal leakage after aortic repair;

New distal SINE;

Abdominal aortic dissection aneurysm diameter ≥5 cm;

Trial design

Design model

Parallel

Treatments tested in this trial

  • WeFlow-EndoPatch Aortic Endovascular Patch System

    Device

    The WeFlow-EndoPatch Aortic Endovascular Patch System for aortic dissection tear is composed of a dissection tear patch system and an adjustable bend conveyor. The patch system is composed of a patch and a conveying steel cable. The patch is pre-installed on the conveying steel cable.

  • Conventional Treatment group

    Other intervention

    Doctors prescribe conventional medicines and regular imaging tests.

Treatment groups

216 Participants
are divided into 2 treatment groups
Group A: EndoPatch GroupExperimental treatment 1 intervention
Group B: Control GroupOther 1 intervention

Trial outcomes

Primary outcomes

1

Treatment Success Rate

The success rate of aortic dissection treatment at 12 months is a composite index, including immediate technical success after surgery, freedom from death or aortic dissection rupture, positive aortic remodeling, and freedom from device and/or procedure related reinterventions.

Time frame
12 months

Secondary outcomes

1

Immediate Technical Success in EndoPatch Group

Immediate technical success is defined as successful delivery of the endopatch conveyors to their predetermined positions, accurate positioning and successful deployment of the patch, safe removal of the delivery device outside the body, and no conversion to thoracotomy.

Time frame
Immediately after the surgery
2

Entry Tears Closure Success in EndoPatch Group

Entry tears closure success is defined as absence of TL or FL backflow through the tears on CTA.

Time frame
30 days, 6 months, and 12 months
3

False Lumen Thrombosis of the Descending Thoracic Aorta

False lumen thrombosis of the descending thoracic aorta (no thrombosis, partial thrombosis, complete thrombosis) observed by postoperative CTA review.

Time frame
30 days, 6 months, and 12 months
4

True Lumen/False Lumen/Maximum Total Diameter of Descending Thoracic Aorta

True lumen diameter, false lumen diameter and maximum total diameter of the descending thoracic aorta observed by postoperative CTA review.

Time frame
30 days, 6 months, and 12 months

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.