Hemodynamic Variations During Remote Ischemic Conditioning in Critical Ill Patients

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-85
SponsorLithuanian University of Health Sciences

About this trial

The main objectives of this study are to evaluate the changes in hemodynamics occurring during the remote ischemic conditioning (RIC) procedure and to compare the hemodynamic responses elicited by passive leg raising before and after the RIC intervention.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

aged over 18 years,

admitted to the intensive care unit,

monitored with a transpulmonary thermodilution device with calibrated pulse contour analysis (Pulsion Medical Systems, Munich, Germany),

decision by the physician in charge to perform passive leg raising.

Disqualifiers

pregnancy,

advanced malignancy,

peripheral artery disease affecting both arms,

head trauma,

Trial design

Design model

Single group

Treatments tested in this trial

  • Remote ischemic conditioning

    Procedure/Surgery

    Remote ischemic conditioning (RIC) procedure comprise three repetitions of brachial cuff inflation to 200 mmHg for five minutes following deflation to 0 mmHg for another five minutes. The procedure overall took 30 minutes.

Treatment groups

50 Participants
are divided into 1 treatment group
Group A: Passive leg raising and Remote ischemic conditioningExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Maximal change in stroke volume index during remote ischemic conditioning (RIC) procedure

Change in this parameter is determined during each inflation and release of the blood pressure cuff.

Time frame
During RIC procedure
2

Maximal change in cardiac index during RIC procedure

Change in this parameter is determined during each inflation and release of the blood pressure cuff.

Time frame
During RIC procedure
3

Maximal change in peripheral perfusion index during RIC procedure

Change in this parameter is determined during each inflation and release of the blood pressure cuff. The perfusion index is measured on a hand that is not equipped with a blood pressure cuff.

Time frame
During RIC procedure
4

The correlation between the maximal changes in stroke volume index, cardiac index, and peripheral perfusion index observed during the RIC procedure and those observed during passive leg raising (PLR).

The maximum changes in these parameters, as determined by the RIC procedure and PLR, were identified, and their correlation was subsequently calculated. The perfusion index is measured on a hand that is not equipped with a blood pressure cuff.

Time frame
During RIC procedure, as well as during passive leg raising.

Secondary outcomes

1

The correlation between the maximum perfusion index (PI), the time to reach maximum PI during cuff release and the maximal changes in stroke volume index, cardiac index and perfusion index observed during PLR.

In this context, PI is measured on the arm where the blood pressure cuff is placed. Upon cuff release, both the maximum PI and the time to reach this maximum are recorded.

Time frame
During RIC procedure, as well as during PLR.

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.