Hybrid Closed-Loop Insulin Delivery After Pancreatectomy

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorCentre Hospitalier Sud Francilien

About this trial

Individuals with diabetes secondary to pancreatectomy experience impaired quality of life, partly due to the challenges of managing highly variable blood glucose levels. Hybrid closed-loop (HCL) automated insulin delivery (AID) systems, widely evaluated in type 1 diabetes, may improve both metabolic outcomes and quality of life in this population.

A review of the literature identified a few observational studies reporting promising results with HCL systems in the context of post-pancreatectomy diabetes. Only one randomized trial has evaluated AID in this population, showing excellent outcomes, but using a complex bihormonal system that is not yet commercially available worldwide. Consequently, there remains a lack of confirmatory evidence regarding the efficacy of commercially available monohormonal HCL systems in individuals with diabetes secondary to pancreatectomy, evidence that is crucial to support broader access to this technology.

The intervention will consist in a 3-month AID treatment combining MiniMed 780 and Simplera.

The control period will consist in 3 months using the Simplera for continuous glucose monitoring, alongside participant usual diabetes treatment.

The primary outcome is the percentage of time that interstitial glucose levels remain within the target range (70-180 mg/dL), as measured by continuous glucose monitoring (CGM, Simplera), over a 3-month period using the MiniMed 780 hybrid closed-loop system, compared to a 3-month period under the participant's usual diabetes treatment.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age from 18 years

History of total or partial pancreatectomy with random C-peptide < 0.3 ng/mL and concomitant blood glucose between 120 and 225 mg/dL (no minimum delay required since surgery)

Total daily insulin dose between 6 units and 250 units

Be affiliated to a French social security scheme

Disqualifiers

Presence of diabetic retinopathy at or beyond severe non-proliferative diabetic retinopathy, not stabilized by ophthalmologic treatment

Usual diabetes treatment with an insulin pump coupled with continuous glucose monitoring with a "suspend before hypoglycemia" system

Pregnant woman or planned pregnancy within the next 6 months

Ongoing or planned chemotherapy that interferes or is expected to interfere with glycemic control or nutritional intake, particularly in cases of clinically significant gastrointestinal toxicity and/or associated systemic corticosteroid therapy, after consultation with the treating oncologist.

Trial design

Design model

Crossover

Treatments tested in this trial

  • MiniMed 780 associated with Simplera

    Device

    MiniMed 780 associated with Simplera

Treatment groups

24 Participants
are divided into 2 treatment groups
Group A: Sequence 1: MiniMed 780 then usual diabetes treatmentExperimental treatment 1 intervention
Group B: Sequence 2: Usual diabetes treatment then MiniMed 780Experimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Percentage of time in range

Percentage of time that interstitial glucose levels remain within the target range (70-180 mg/dL), as measured by continuous glucose monitoring (CGM, Simplera), over a 3-month period using the MiniMed 780 hybrid closed-loop system compared to a 3-month period with participant's usual diabetes treatment.

Time frame
At 3 months

Secondary outcomes

1

HbA1c

HbA1c level, measured by laboratory blood testing, after 3 months of treatment with MiniMed 780 compared to after 3 months of the participant's usual diabetes treatment.

Time frame
At 3 months
2

Percentage of time below range

The percentage of time that interstitial glucose levels remain below 70 mg/dL, as measured by CGM, over a 3-month period using MiniMed 780, compared to a 3-month period under the participant's usual diabetes treatment.

Time frame
At 3 months
3

Glucose coefficient of variation

The glucose coefficient of variation (CV), as measured by CGM, over a 3-month period using MiniMed 780 hybrid closed-loop system, compared to a 3-month period under the participant's usual diabetes treatment.

Time frame
At 3 months
4

Frequency of acute metabolic events

The frequency of severe acute metabolic events combining frequency of severe hypoglycemia, diabetic ketoacidosis (DKA), and diabetes-related emergency visit or unplanned hospitalisation, over a 3-month period using MiniMed 780 hybrid closed-loop system, compared to a 3-month period under the participant's usual diabetes treatment.

Time frame
At 3 months

Other outcomes