About this trial
The study will evaluate the efficacy and safety of transcatheter aortic valve implantation (TAVI) using the Hydra transcatheter aortic heart valve (THV) series, in patients with severe aortic stenosis up to 1-year after the procedure. This will include an evaluation of the preservation of coronary access post implant by attempting to selectively engage both the right and left coronary arteries through standardised angiographic views.
The study will also examine the utility of 72 hours of post discharge remote ambulatory continuous electrocardiogram (ECG) monitoring using the novel Checkpoint Cardio System where it is clinically appropriate.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients with severe aortic stenosis eligible for transfemoral TAVI procedure as per local Heart Team evaluation
Full understanding and willing to provide informed consent to study enrolment
Age ≥ 18 years
Disqualifiers
Contraindications to TAVI (e.g., anatomically phenotypes, intracardiac mass, thrombus, vegetation, endocarditis)
Refusal to provide informed consent to study enrolment
Patients with severe aorta or peripheral artery disease precluding transfemoral approach of TAVI
Patients with significant calcification of the aortic annulus and in the Left Ventricular Outflow Tract (LVOT), or/and excess calcium within each cusp, or those who are deemed unsuitable for the Hydra THV series based on the clinical judgment of the Investigator.
Trial population
Patient with severe aortic valve stenosis
Trial design
Case-only
Prospective
Treatments tested in this trial
Hydra transcatheter aortic valve (THV) series
DeviceThe Hydra device consists of a self-expanding nitinol frame and three bovine pericardial leaflets in supra-annular position.
Treatment groups
Trial outcomes
Primary outcomes
Primary safety endpoint
Early safety as defined by VARC-3 as composite of: * Freedom from all-cause mortality; * Freedom from all stroke; * Freedom from VARC 3 type 3-4 bleeding; * Freedom from major vascular, access-related, or cardiac structural complication; * Freedom from acute kidney injury stage 3 or 4; * Freedom from moderate or severe aortic regurgitation; * Freedom from new permanent pacemaker due to procedure-related conduction abnormalities; * Freedom from surgery or intervention related to the device.
Primary performance endpoint
Device success as defined by VARC-3 as composite of: * Technical success; * Freedom from mortality; * Freedom from surgery or intervention related to the device or to a major vascular or access related or cardiac structural complication; * Intended performance of the valve (mean gradient \<20mmHg, peak velocity \<3 m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation).
Secondary outcomes
Technical success
As per VARC-3 defined criteria
Cardiovascular mortality
All-cause mortality
All stroke