There is evidence that central venous catheters made of the permanent and non-eluting integral polymer Endexo® are more resistant to intraluminal thrombosis. This has a direct reducing effect on catheter malfunctions. Indirectly, due to reduced handling of the dysfunctional catheter, this may lead to a diminished rate of catheter related infections. Since catheter malfunctions and infections represent leading complications in a dialysis population, dialysis catheters produced with Endexo® technology have the potential to have beneficial clinical effects. In addition to improving patient outcomes, this could also reduce overall costs. In this pilot study the tunneled hemodialysis catheter BioFlo Duramax with Endexo® technology (Merit Medical, Utah, USA) will be compared with historical catheter dysfunction rates in standard tunneled dialysis catheters (silicone or polyurethane) in chronic dialysis population.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Adult patients aged greater than 18 years
Written informed consent
Requirement for hemodialysis using a tunneled dialysis catheter
Disqualifiers
Children aged less than 18 years
Uncontrolled infection; defined as positive blood culture in the past seven days before catheter insertion and/ or elevated C-reactive protein [CRP >5 mg/dl (normal <0.5 mg/dl)] at screening
Trial design
Single group
Treatments tested in this trial
Insertion of a tunneled hemodialysis catheter BioFlo Duramax with Endexo® technology (Merit Medical, Utah, USA)
DeviceIn this pilot study the tunneled hemodialysis catheter BioFlo Duramax with Endexo® technology (Merit Medical, Utah, USA) will be compared with historical catheter dysfunction rates in standard tunneled dialysis catheters (silicone or polyurethane) in chronic dialysis population.
Treatment groups
Trial outcomes
Primary outcomes
Catheter dysfunction
Catheter dysfunction will be defined as inadequate blood flow during dialysis (blood flow \< 200mL/min or \>30% less than the average of the previous 10 sessions) and if present before or during dialysis, patient repositioning or reversal of catheter lines will be performed. If not successful, Taurolock Urokinase with a final Urokinase of 50.000 IU will be instilled per lumen either with a 30-minute dwell time before dialysis or as CLS in the inter-dialytic time as rescue. If urokinase is not effective after repeated use the dialysis catheter will be removed.
Secondary outcomes
Need for reversal of catheter lines
Rescue with high dose urokinase (50.000 IU per lumen)
Total number of catheter-related infections
Catheter-related infections will be defined as positive bacterial blood culture drawn from the dialysis catheter in a symptomatic patient with fever or chills associated with dialysis and no apparent other source of infection. Blood cultures will be taken using aseptic technique from each lumen of the tunneled catheter and in addition from a peripheral vein whenever possible to determine the differential time to positivity.
Catheter-related infections free survival