About this trial
Taking blood cultures is an important and very common procedure in intensive care units due to the high incidence of sepsis and the need for rapid and accurate identification of bacteremia. However, despite the importance of taking a sufficient volume of blood for the purpose of identifying bacterial growth in the blood, the average blood volume in blood cultures at our institution ranges from 3.5-4 ml per bottle (where the desired volume is 10 ml). Taking an insufficient amount of blood reduces the ability of the bacteriological laboratory to detect bacterial growth and thus may lead to a delay or missed diagnosis of bacteremia, identification of the pathogen, and adjustment of appropriate treatment according to sensitivities.
In intensive care units, most patients are monitored using an arterial catheter, which allows for frequent blood tests without the need to puncture the patient. Following recently published studies that showed that there is no significant difference in the incidence of contamination when taking blood cultures from an arterial catheter compared to a peripheral vein puncture, and in order to improve our ability to identify bacteremia, it was decided to implement a new protocol in the General Intensive Care Unit that includes taking blood cultures from an arterial catheter. According to the new protocol, it was decided that when taking blood cultures from a patient with an arterial catheter, one pair of cultures should be taken from the arterial catheter and another pair from a peripheral vein puncture.
In this study, we would like to examine the contamination rate of blood cultures, the identification of true bacteremia, and the collection of appropriate blood volume and number of blood specimens taken in patients hospitalized in the General Intensive Care Unit at our institution, while analyzing differences between the period before the implementation of the new protocol and the period after the implementation, and differences between cultures taken from an arterial catheter and from a peripheral vein puncture.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
None
Trial population
All patients admitted to the intensive care unit in our hospital between January 2024 and January 2027 who had blood cultures taken as part of their routine care.
Trial design
Case-control
Prospective
Treatments tested in this trial
Blood culture taken from an arterial catheter
Diagnostic testBlood culture taken from an arterial catheter (instead of peripheral venous puncture)
Treatment groups
Trial outcomes
Primary outcomes
Contamination and real bacteremia detection rates
To examine whether there are differences between the contamination rate and the detection rate of true bacteremia between blood cultures from an arterial catheter and blood cultures from a fresh puncture of a peripheral vein.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.