Impedance Plethysmography Based Deep Vein Thrombosis Monitoring During Catheter-directed Thrombolysis

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorTampere University

About this trial

The purpose of this study is to collect data on blood circulation using a multi-frequency impedance plethysmography device developed in the ThrombUS+ project. Impedance plethysmography (IPG) is a non-invasive method that measures changes in blood volume using electrodes placed on the skin. The collected data will be used for device development, the improvement of diagnostic data analysis methods, and AI training.

A total of 40 participants will be recruited for this study, with 20 healthy volunteers in Tampere University and 20 patients undergoing thrombolytic therapy for DVT at Tampere University Hospital.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Age: 18 or older;

DVT detected on other lower limb;

Suitable for CDT treatment;

Ability to give informed consent;

Disqualifiers

Age under 18 years;

Inability to give informed consent;

Denial;

Too injured skin in the measurement area

Trial population

Tampere

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Impedance plethysmography IPG

    Device

    IPG signal is measured with ThrombUS+ prototype device

  • Venous Occlusion Plethysmography VOP

    Device

    In VOP measurement, a temporal blood restriction is caused by an occlusive cuff blocking venous outflow but allowing arterial inflow. The cuff intervention causes a change in venous blood volume, and it can be measured by electrical impedance plethysmography (IPG).

  • Breathing and leg movement exercise

    Other intervention

    The first exercise is the Valsalva maneuver, where the subject first inhales and then pushes out the breath while the larynx is closed. In the second exercise, the subject inhales for approximately 10 seconds, holds the breath for approximately 5 seconds, and then breathes out. Finally, the subject moves the ankles to contract calf muscles, and further to cause changes in venous blood volume. The IPG signal is measured on both calves by ThrombUS+ prototype device during these exercises.

Treatment groups

40 Participants
are divided into 2 treatment groups
Group A: Patients3 interventions
Group B: Healthy volunteers3 interventions

Trial outcomes

Primary outcomes

1

Impedance plethysmography (IPG) data during CDT treatment

Time frame
From enrollment to the end of the CDT treatment (up to 2 days)
2

Impedance plethysmography (IPG) data from healthy volunteers

Time frame
From enrollment to the end of measurements (up to 2 hours)