About this trial
Robotic lower limb exoskeletons aim to improve or augment limb functions. Automatic modulation of robotic assistance is very important because it can increase the assistive outcomes and guarantee safety when using exoskeletons.
However, this automatic assistance adjustment is challenging due to person-to-person and day-to-day variations, as well as the time-varying complex human-machine-interaction forces. In recent years, human-in-the-loop optimization methods have been investigated to reduce participants' metabolic costs by providing personalized assistance from robotic exoskeletons. However, metabolic cost measure is noisy and the experimental protocol is usually relatively long. In addition, the influence of exoskeleton control on this human state in terms of energetic cost is unclear and indirect. More importantly, the optimization by reducing metabolic cost is found to affect human gait patterns and cause undesired outcomes. In this study, new evaluation measures other than metabolic cost will be investigated to optimize the assistance from a powered hip exoskeleton based on a reinforcement learning method. It is hypothesized that the new reinforcement learning-based optimal control approach will produce personalized torque assistance, reduce human volitional effort, and improve balance and other performance during walking tasks. Both participants without and with neurological disorders will be included in this study.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Between 18 and 64 years old
Live in the United States
Able to understand study requirements and sign an informed consent
Have full range of motion in your hip joint
Disqualifiers
Cannot follow instructions or provide feedback due to cognitive or language limitations
Suffered from a stroke that affects balance or walking
Use an electronically controlled medical device, such as a pacemaker, implanted defibrillator, or drug pump
Pregnancy
Trial design
Crossover
Treatments tested in this trial
A zero impedance mode, controlling a wearable bilateral hip exoskeleton
Other interventionThe bilateral hip exoskeleton has two degrees of freedom to enable the hip joint extension and flexion movement on both left and right sides. The zero impedance mode will not provide any assistance or resistance to the hip joints.
A personalized optimal assistance mode, controlling a wearable bilateral hip exoskeleton
Other interventionThe personalized optimal assistance mode includes both individualized hip flexion and hip extension assistance, which is determined by using the reinforcement learning-based automatic control parameters tuning during walking tasks. Therefore, the personalized optimal assistance will be able to improve the walking gait performance and reduce the energetic consumption.
A free walking mode, without wearing a wearable bilateral hip exoskeleton
Other interventionThe free walking mode will not include the usage of the wearable bilateral hip exoskeleton, and the human walking subjects will conduct pure natural walking tasks.
Treatment groups
Trial outcomes
Primary outcomes
Human lower limb joints angular position
The investigators will measure the angular position \[rad\] on the left and right hip joints by using the embedded incremental encoders that are installed on the hip exoskeleton. The investigators will measure the angular position \[rad\] on the left and right knee and ankle joints using the motion capture system containing the 3-dimensional coordinates of reflective markers.
Human lower limb joints angular velocity
The investigators will measure the angular velocity \[rad/sec\] on the left and right hip joints by using the embedded incremental encoders that are installed on the hip exoskeleton. The investigators will measure the angular velocity \[rad/sec\] on the left and right knee and ankle joints using the motion capture system containing the 3-dimensional coordinates of reflective markers. The calculation of the angular velocity is the time-derivative of the angular position in the unit of \[mm\].
Secondary outcomes
Human walking stride length
The investigators will measure the walking stride length \[mm\] of the left and right legs using the motion capture system containing the 3-dimensional coordinates of reflective markers on each foot.
Human walking symmetry
The investigators will calculate the gait symmetry (normalized value between -1 and 1) based on the measurements of left and right stride length \[mm\].
Human lower limb joints torque
The investigators will measure the biological joint torque \[Nm\] on each joint of the lower extremities. The investigators will measure the assistance torque \[Nm\] from the hip exoskeleton.
Human lower limb joints power
The investigators will measure the biological joint power \[W\] on each joint of the lower extremities. The investigators will measure the assistance power \[W\] from the hip exoskeleton.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
North Carolina State University
Lead sponsor
University of North Carolina, Chapel Hill
Collaborator