The goal of this clinical trial is to improve the combined use of PET/CT and MRI for imaging of the breast. PET/CT and MRI are usually performed in different body positions, which can change the shape and position of the breast and make it difficult to accurately align findings between the two examinations.
The main questions this study aims to answer are:
Can dedicated breast positioning during PET/CT reduce differences in breast shape and position compared with MRI?
Can image registration methods further improve the alignment of PET/CT and MRI images of the breast?
How accurately can findings seen on PET/CT be transferred to the corresponding location on MRI?
Participants in this study are breast cancer patients who are already scheduled to undergo PET/CT and PET/MRI as part of their clinical care. As part of the study, they will undergo an additional low-dose CT scan and an additional PET acquisition in a dedicated prone breast position. The additional PET images will be acquired using the tracer that has already been administered for the clinically indicated PET examination; no additional tracer injection is required.
The imaging data will then be used to develop and evaluate different methods for aligning PET/CT and MRI images of the breast.
The study does not investigate a new drug or treatment.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Female sex
Clinically indicated PET/CT and PET/MRI of the breast
Histologically confirmed breast cancer
Disqualifiers
Age under 18 years
Pregnancy
Lack of capacity to provide informed consent
Possible conception within the previous 14 days
Trial design
Single group
Treatments tested in this trial
Prone Breast PET/CT Acquisition
Diagnostic testParticipants undergo an additional PET acquisition and a low-dose CT acquisition in a dedicated prone breast position using a breast-specific positioning setup. The study-specific imaging procedure takes approximately 6-10 minutes. The PET acquisition is performed after the clinically indicated radiotracer administration and does not require an additional tracer injection. The study-specific acquisition is designed to reduce differences in breast shape and position between PET/CT and prone breast MRI and to provide image data for subsequent multimodal image registration.
Treatment groups
Trial outcomes
Primary outcomes
Target Registration Error After Multimodal Breast Image Registration
Target Registration Error (TRE) will be used to quantify the spatial accuracy of registration between corresponding breast imaging datasets. TRE will be calculated as the distance in mm between predefined corresponding anatomical or imaging reference points after registration. Lower TRE values indicate greater registration accuracy. Registration performance will be assessed for datasets acquired in different body positions and for datasets acquired in comparable prone breast positions.
Mean Three-Dimensional Structural Similarity Index (3D-SSIM) Between Registered PET Datasets
Structural similarity between the registered PET datasets acquired as part of PET/CT and PET/MRI will be assessed using the three-dimensional Structural Similarity Index (3D-SSIM), implemented in Python using the scikit-image library. The index provides a dimensionless measure of similarity in spatial image patterns, with higher values indicating greater structural similarity and a value of 1 representing perfect similarity. The 3D-SSIM will be calculated within the registered breast image volume for each registration approach and acquisition setting to assess registration performance and the effect of comparable breast positioning on registration quality.
Secondary outcomes
Absolute Difference in SUVmax After Image Deformation
The maximum standardized uptake value (SUVmax) will be measured in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in SUVmax between the original and deformed datasets will be calculated to quantify changes in quantitative PET information introduced by image deformation. The mean absolute difference in SUVmax will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.
Absolute Difference in SUVmean After Image Deformation
The mean standardized uptake value (SUVmean) will be measured in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in SUVmean between the original and deformed datasets will be calculated to quantify changes in quantitative PET information introduced by image deformation. The mean absolute difference in SUVmean will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.
Absolute Difference in SUVpeak After Image Deformation
The peak standardized uptake value (SUVpeak) will be measured in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in SUVpeak between the original and deformed datasets will be calculated to quantify changes in quantitative PET information introduced by image deformation. The mean absolute difference in SUVpeak will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.
Absolute Difference in SUVmax-Based Tumor-to-Background Ratio After Image Deformation
The tumor-to-background ratio based on maximum standardized uptake value (TBRmax) will be calculated in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in TBRmax between the original and deformed datasets will be calculated to quantify changes in quantitative PET contrast introduced by image deformation. The mean absolute difference in TBRmax will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: