Improving Outcomes in Adolescent Inpatient Depression With Deep Transcranial Magnetic Stimulation

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age14-18
SponsorChildren's Hospital Medical Center, Cincinnati

About this trial

Evaluate the feasibility, safety, and preliminary efficacy of deep Transcranial Magnetic Stimulation (dTMS) as an adjunctive treatment for adolescents hospitalized with major depressive disorder (MDD).

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Fluent in English and able to volunteer in the informed consent process and provide spontaneous narrative description of key elements, risks, and benefits of the study.

Aged 14 years to 18 years, inclusive.

Diagnosis of MDD based on psychologist diagnosis and DSM-5-checklist based interview.

Symptoms of moderate to severe depression according to Hamilton Depression Rating Scale Score > 20.

Disqualifiers

Participation in an investigational drug trial within the past three months.

Contraindications to Transcranial Magnetic Stimulation including, but not limited to, a history of epilepsy, the presence of metallic foreign bodies, or implanted medical devices (e.g. ventriculoperitoneal shunt, pacemaker, medical pump).

Actively psychotic (i.e. disorganized, delusional, paranoid, or having hallucinations)

Actively suicidal (have a suicidal plan and intent and is on 1:1 close observation)

Trial design

Design model

Parallel

Treatments tested in this trial

  • Transcranial Magnetic Stimulation

    Device

    The Brainsway Deep TMS System with the FDA-cleared H7 Coil will be used to deliver all accelerated theta burst stimulation (aTBS) sessions. The H7 Coil is designed to target deeper and broader brain regions, including the prefrontal and anterior cingulate cortices, and has FDA 510(k) clearance for treatment of OCD and MDD in adults. Stimulation will follow a standardized accelerated theta burst protocol: triplet 50 Hz bursts delivered every 200 ms (5 Hz), in 2-second trains with 8 seconds off, at 90% RMT, totaling 600 pulses per session. Participants will receive five sessions per day over five business days with 30-minute breaks between the third and fourth sessions and exceeding or preceding these breaks will not be a protocol deviation. The sham coil mimics sensory experience without delivering stimulation.

  • Transcranial Magnetic Stimulation Sham

    Device

    Investigators will use a robust sham technique that is manufacturer-designed to mimic the auditory and tactile sensations of active TMS without delivering effective magnetic stimulation to the brain. The Brainsway Sham H7-CoilTM will be utilized for treatment delivery. The H-7 coil already has a built-in sham system that can operate as a placebo. Only the TMS operators will have access to intervention assignments, the rest of the study team will not have access to assignments to maintain the blinded status of participants, caregivers, and raters.

Treatment groups

60 Participants
are divided into 2 treatment groups
Group A: Active dTMS TreatmentActive comparator 1 intervention
Group B: Sham controlledSham comparator 1 intervention

Trial outcomes

Primary outcomes

1

Tolerability and Safety

We will collect and summarize descriptive data on discomfort and adverse events using Sections IV of the TMS Adverse Events and Associated Sensations Questionnaire (TMSens\_Q). This captures typical sensory experiences or side effects, e.g. scalp tingling or headache) as well as adverse events (e.g. syncope). Tolerability will be characterized based on sensory experiences and side effects, comparing active to sham treatment. Safety will be further assessed by the rate of early discontinuation due to intolerability or adverse events using the CCHMC Adverse Event form. Tolerability: Unit of measure: frequency and severity of sensory experiences and adverse events, e.g. scalp tingling or headache, syncope). Safety: Unit of measure: Rate of early discontinuation or withdrawal of treatment due to intolerability or adverse events.

Time frame
Completed before and immediately after the intervention

Secondary outcomes

1

Hospitalization

Time to first psychiatric readmission or emergency department (ED) visit for depression or suicidality within 12 months post-discharge. Unit of Measure: Time to first psychiatric readmission or ED visit (months).

Time frame
Completed monthly for the first 6 months, 9th and 12th month follow up
2

Depression Symptoms

Change in depressive symptom severity as rated by the Hamilton Depression Rating Scale (HDRS-17). The HDRS is a 17-item rating scale administered by a trained rater following a semi-structured interview. Scores of 0-7 are generally within the normal range, and a score of 20 or higher indicates moderate depression severity. Research suggests that a decrement of 7 points on the HAMD-17 represents minimally clinically important differences from patient perspectives. Unit of Measure: HDRS-17 total score.

Time frame
Completed at screening, same day after the intervention, monthly for 6 months, then at 9th and 12th month follow up
3

Suicide Risk

Change in suicidal ideation and behavior from screening to follow-up, assessed using the Columbia-Suicide Severity Rating Scale (C-SSRS). Unit of Measure: C-SSRS severity.

Time frame
Completed at screening, same day after the intervention, monthly for 6 months, then at 9th and 12th month follow up

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.