Influence of Intermittent Hypoxia on Loop Gain in Healthy Subjects

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-45
SponsorPoitiers University Hospital

About this trial

Sleep apnoea-hypopnoea syndrome (SAHOS), which causes numerous comorbidities, particularly cardiovascular ones, is widespread worldwide today and incurs significant healthcare costs.

Current research in this field focuses on identifying different phenotypes in affected patients in order to provide more personalised treatment.

One of these phenotypes appears to be linked to instability in ventilatory control due to an increase in loop gain (LG) in these subjects.

However, the pathophysiology of this ventilatory control instability due to increased LG is not fully understood. It is still difficult to determine whether subjects have an intrinsically high LG or if exposure to intermittent hypoxia during OSA promotes an increase in LG.

It has also been demonstrated that OSA causes vascular hyperreactivity by increasing oxidative stress through elevated ROS production. This leads to endothelial dysfunction in response to intermittent hypoxia associated with apnoea. Extracellular vesicles (microvesicles and exosomes) have been shown to play a role in this endothelial response. These extracellular vesicles are essential for intercellular communication in both physiological and pathological situations, such as SAHOS.

Therefore, the objective of this research is to determine whether exposure to intermittent hypoxia and changes in microvesicle phenotype could influence LG, which could lead to new therapeutic advances in the context of SAHOS.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Healthy subjects aged 18 to 45

BMI between [18-25] kg/m2

No known sleep disorders

Free subjects, not under guardianship or curatorship or subordination

Disqualifiers

SpO2 < 97% in ambient air at rest.

Detection of pregnancy in women of childbearing age.

Detection of acute mountain sickness (Lake Louise score > 0).

Abnormalities in spirometry, ventilatory polygraphy, electrocardiogram, and/or hemoglobinometry prior to randomization.

Trial design

Design model

Crossover

Treatments tested in this trial

  • Intermittent hypoxia

    Procedure/Surgery

    The volunteer will remain at rest in the hypoxic chamber, experiencing intermittent hypoxic conditions cyclically every 6 minutes. During one third of the cycle, they will be exposed to hypoxia in order to reduce SpO₂ to between 85% and 90%. Then, during two thirds of the cycle, they will receive oxygenation at a rate of 1 L/min (with possible subject-dependent modulations), with the aim of achieving an SpO₂ of greater than 95%. To make the hypoxia intermittent, the volunteer will also be given a medium-concentration oxygen mask that provides intermittent airflow, controlled by the D-6341 mass flow controller.

  • Normoxia

    Procedure/Surgery

    The participant will remain at rest in the hypoxic chamber under normoxic conditions. To prevent the volunteer from becoming aware of the conditions to which they are exposed, an air flow rate of 1 L/min will be used to simulate intermittent oxygenation.

Treatment groups

40 Participants
are divided into 2 treatment groups
Group A: Arm A : ambient air then intermittent hypoxiaExperimental treatment 2 interventions
Group B: Arm B : intermittent hypoxia then ambient airExperimental treatment 2 interventions

Trial outcomes

Primary outcomes

1

The change in Loop Gain before and after 6 hours of experimental condition (intermittent hypoxia or ambient air).

Loop gain is the product of 'controller gain' (ventilatory responsiveness to CO₂ above eupnoea) and 'plant gain' (the ventilatory increase required for a given reduction in PaCO₂). The following ventilatory parameters will be measured using a gas exchange measuring device to calculate loop gain, plant gain and controller gain: PETCO₂ (in mmHg), PETO₂ (in mmHg) and Minute ventilation (VE) measured in mL/min (tidal volume x respiratory rate). For each experimental condition (test-hypoxia or control-ambient air), loop gain will be measured before the experimental condition (after 30 minutes of rest) and after the experimental condition (20 minutes before leaving the hypoxic chamber). The change in loop gain is defined as the difference between the average values (over 5 minutes) of the loop gain before and after the experimentation.

Time frame
6 hours of experimental condition

Secondary outcomes

1

The change in controller gain before and after 6 hours of experimental condition (intermittent hypoxia or ambient air)

The following ventilatory parameters will be measured using a gas exchange measuring device to calculate loop gain, plant gain and controller gain: PETCO₂ (in mmHg), PETO₂ (in mmHg) and Minute ventilation (VE) measured in mL/min (tidal volume x respiratory rate). For each experimental condition (test-hypoxia or control-ambient air), controller gain will be assessed before the experimental condition (after 30 minutes of rest) and after the experimental condition (20 minutes before leaving the hypoxic chamber). The change in controller gain is defined as the difference between the average values (over 5 minutes) of the controller gain before and after experimental condition.

Time frame
6 hours of experimental condition
2

The change in plant gain before and after 6 hours of experimental condition (intermittent hypoxia or ambient air)

The following ventilatory parameters will be measured using a gas exchange measuring device to calculate loop gain, plant gain and controller gain: PETCO₂ (in mmHg), PETO₂ (in mmHg) and Minute ventilation (VE) measured in mL/min (tidal volume x respiratory rate). For each experimental condition (test-hypoxia or control-ambient air), plant gain will be assessed before the experimental condition (after 30 minutes of rest) and after the experimental condition (20 minutes before leaving the hypoxic chamber). The change in plant gain is defined as the difference between the average values (over 5 minutes) of the plant gain before and after experimental condition.

Time frame
6 hours of experimental condition
3

The change in the quantity of extracellular vesicles before and after 6 hours of experimental condition (intermittent hypoxia versus ambient air)

The quantity of extracellular vesicles is assessed from blood samples using flow cytometry with specific antibodies. Blood samples are collected before the experimental condition (after 30 minutes of rest) and after the experimental condition (after leaving the hypoxic chamber). This change is expressed as the difference in the following extracellular vesicle concentrations before and after experimental conditioning: * EVs from platelets expressing CD41 * EVs from erythrocytes expressing CD235a * EVs from leukocytes expressing CD45 * EVs from endothelial cells expressing CD146 * EVs from granulocytes expressing CD66b and CD11b * EVs from activated leukocytes expressing CD62L * EVs from activated endothelial cells expressing CD62E * EVs from activated platelets expressing CD62P * CD62P/platelet ratio * EVs carrying the PSGL-1 ligand expressing CD162 * EVs carrying phosphatidylserine expressing annexin V

Time frame
6 hours of experimental condition
4

Correlation between the change in quantity of extracellular vesicles and change in loop gain

The change in the quantity of extracellular vesicles is defined as the difference of the extracellular vesicle concentration before and after the experimental condition (intermittent hypoxia and ambient air). The change in loop gain is defined as the difference of the loop gain values before and after the experimental condition (same definition as the primary outcome). We are interested in the following extracellular vesicles: CD41, CD235a, CD45, CD146, CD66b, CD11b, CD62L, CD62E, CD62P and CD62/platelet annexin V.

Time frame
6 hours of experimental condition