Inhaler Adherence and Inhalation Technique Assessed by a Smart Spacer in Patients With Severe Asthma on Biologics

ConditionAsthma
Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorUniversity Medical Center Groningen

About this trial

Severe refractory asthma affects about 3.5% of asthma patients, often necessitating biologic therapy in addition to standard treatment. However, little is understood about maintenance and reliever inhalation medication adherence in these cases which might impact overall biologic response. Objectively monitoring inhalation medication adherence remains a significant challenge. The Smart AeroChamber® device, capable of measuring adherence and inhalation technique, is untested in severe asthma patients on biologics, presenting a potentially cost-effective solution to monitor adherence and better understand treatment response.

This study aims to assess the feasibility of the Smart AeroChamber® device in severe asthma patients on biologic therapy, with objectives to:

1. Evaluate inhalation medication adherence patterns and inhaler technique, and comparing that adherence data with traditional measures e.g. the Test of Adherence to Inhalers (TAI), and an inhalation technique checklist. 2. Investigate the association between inhaled medication adherence and clinical outcomes such as exacerbations, short-acting beta-agonists (SABA) use, oral corticosteroids use (OCS), Fractional Exhaled Nitric Oxide (FeNO), blood eosinophil count, and Asthma Control Questionnaire (ACQ) scores. 3. Assess patient and healthcare provider satisfaction and usability of the Smart AeroChamber® device.

The study design is prospective and observational, with a sample size of 110 adult patients diagnosed with severe asthma using biologic therapy. Participants will be followed for 12 months, during which they will receive Smart AeroChamber® devices. These devices will measure medication adherence and inhaler technique, and undergo assessments of clinical outcomes at regular intervals. Usability and satisfaction will also be evaluated using the Systems Usability Scale (SUS) in patients and healthcare professionals.

The study will be conducted across five severe asthma clinics in the Netherlands. Data analysis will involve comparing the inhalation medication adherence data with traditional measures for adherence and inhalation technique, assessing clinical outcomes, and evaluating usability and satisfaction. The findings from this study will provide insights into the feasibility and effectiveness of using digital devices like the Smart AeroChamber® to support medication adherence and possibly improve outcomes in patients with severe asthma on biologic therapy.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age ≥ 18 years.

Confirmed asthma diagnoses (≥12% and >200 ml reversibility in FEV1 or positive histamine/methacholine provocation test or FeNO ≥50) according to the asthma guidelines

Diagnosed with severe, refractory asthma with eligibility for treatment with specific asthma biologics (omalizumab, mepolizumab, benralizumab, reslizumab, dupilumab)

Using medium or high ICS + LABA +/- LAMA+/-SABA) by pMDI+spacer

Disqualifiers

The use of the Symbicort Aerosol or the Trixeo Aerosphere in combination with a spacer (these inhalers are not compatible with the smart spacer)

Inability to sufficiently understand and read the Dutch language

Current pregnancy

Currently terminally ill

Trial population

Participants aged over 18 years, diagnosed with severe asthma by a physician according to GINA guidelines. They must be using a biologic medication (omalizumab, mepolizumab, reslizumab, benralizumab, or dupilumab) and medium or high dose ICS + LABA with or without LAMA and/or SABA via pMDI and spacer.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Smart spacer

    Device

    Participants' inhalation medication adherence and inhalation technique will be monitored using a smart spacer. Their usual medication regime will be continued and they will not receive information about their adherence or inhalation technique measured by the spacer during the follow-up year (except for any interventions that will be done in standard care).

Treatment groups

110 Participants
are divided into 1 treatment group
Group A: Severe asthma patients on biologics1 intervention

Trial outcomes

Primary outcomes

1

Comparative analysis of smart spacer medication adherence and inhaler technique against Test of Adherence to Inhalers (TAI-12)

An evaluation of the inhalation adherence patterns and inhaler techniques of patients utilizing smart spacer devices in comparison to traditional inhaler usage assessed by the Test of Adherence to Inhalers (TAI-12). TAI is a questionnaire which identifies patients with low adherence, determines the degree of adherence and gives an idea of the type or pattern of non-compliance. The TAI-12 consists of 10 questions for the patient and 2 questions for the healthcare provider and identifies patients with poor adherence and their degree of adherence. The scoring for the patient part is: for each question ranges from 1 to 5 (1 = worst compliance to 5 = best compliance). All items provide a total score of between 10 (minimum) and 50 (maximum). A higher score is related to better adherence. The scoring of the healthcare provider part is: a minimum of 2 points and a maximum of 4 points. A higher score also relates to a better adherence.

Time frame
TAI is measured at baseline and 12 months
2

Comparison of smart spacer medication adherence patterns (adherence and inhaler technique) with inhaler checklist examined by pulmonologist or pulmonary nurse

An evaluation of the inhalation adherence patterns and inhaler techniques of patients utilizing smart spacer devices in comparison to traditional inhaler usage assessment by healthcare professionals using an inhalation technique checklist. The inhalation technique checklist is created by following the national inhalation technique guidelines by the Lung Foundation in The Netherlands (Long Alliantie Nederland, LAN), specifically for using a pMDI in combination with a spacer. The checklist consists of 8 points to assess the inhalation technique on (from the preparation of the device, to the positioning of the device and posture of the patient, and the actual inhalation).

Time frame
Inhaler checklist is assessed at baseline and 12 months

Secondary outcomes

1

Assessing the association of smart spacer assessed adherence with annual exacerbation rate

An assessment of the association between inhalation medication adherence measured by smart spacer devices and the annual exacerbation rate. The annual exacerbation rate will include the number of exacerbations of the participant in the one-year follow-up and the severity of the exacerbation (e.g. increased reliever use, oral corticosteroid use, emergency room visit, hospitalization).

Time frame
Over a period of 12 months
2

Assessing the association of smart spacer assessed adherence with reliever inhaler use (e.g. SABA)

An examination of the possible association between inhalation medication adherence measured by smart spacer devices and the use of reliever medication. The use of reliever medication will also be monitored by the smart spacer and it is included as a question in the Asthma Control Questionnaire (question 6).

Time frame
Over a period of 12 months
3

Assess the association of smart spacer assessed adherence with oral corticosteroids use

An examination of the possible association between inhalation medication adherence measured through smart spacer devices and the use of oral corticosteroids (OCS). The use of OCS will be defined as total annual OCS exposure (in milligrams) as well as the number of high dose (\> 30 milligrams) short courses (between 3 to 14 days).

Time frame
Over a period of 12 months
4

Assess the association of smart spacer assessed adherence with FeNO results

An examination of the possible association between inhalation medication adherence measured through smart spacer devices and FeNO measurements. Fractional exhaled nitric oxide (FeNO) serves as an indicator of inflammation in asthma. It has been employed as a measure to detect non-compliance with inhaled corticosteroid (ICS) therapy. Individuals who do not adhere to ICS treatment typically exhibit elevated FeNO levels since ICS effectively suppress FeNO. A high FeNO level despite ICS usage suggests ongoing inflammation in the airways due to asthma, increasing the likelihood of exacerbations. The difference in FeNO measured at baseline and 12 months will be compared the overall ICS adherence.

Time frame
FeNO is measured at baseline and 12 months

Other outcomes

1

Assess usability and patient satisfaction using the System Usability Scale

The usability and patient satisfaction will be measured using the System Usability Scale (SUS). The SUS provides a simple and standardized effective tool for assessing usability and patient satisfaction with healthcare technologies. The SUS consists of ten statements related to usability, with respondents asked to rate their level of agreement with each statement on a five-point Likert scale ranging from "Strongly Disagree" (1 point) to "Strongly Agree" (5 points). The score for the five odd-numbered questions is determined by subtracting 1 from the scored points (X-1). The score for the five even-numbered questions is calculated by deducting the scored points from 5 (5-X). By adding up these two scores and multiplying the total by 2.5, the SUS score is calculated. The total scores range from 0 to 100. Higher scores indicate better usability, with scores above 70 considered above average and scores above 80 indicating excellent usability.

Time frame
SUS is measured at 12 months
2

Assess usability and healthcare provider satisfaction using the System Usability Scale

The usability and healthcare provider satisfaction will be measured using the System Usability Scale (SUS). The SUS provides a simple and standardized effective tool for assessing usability and healthcare providers' satisfaction with healthcare technologies. The SUS consists of ten statements related to usability, with respondents asked to rate their level of agreement with each statement on a five-point Likert scale ranging from "Strongly Disagree" (1 point) to "Strongly Agree" (5 points). The score for the five odd-numbered questions is determined by subtracting 1 from the scored points (X-1). The score for the five even-numbered questions is calculated by deducting the scored points from 5 (5-X). By adding up these two scores and multiplying the total by 2.5, the SUS score is calculated. The total scores range from 0 to 100. Higher scores indicate better usability, with scores above 70 considered above average and scores above 80 indicating excellent usability.

Time frame
SUS is measured at 12 months

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

University Medical Center Groningen

Lead sponsor

Trudell Medical International

Collaborator