About this trial

The study investigates the influence of three types of ventilation mode by using Bi-Level positive airway pressure (pinsp 20 mbar, PEEP 5, AF 10/min) with two different types of ventilators ( Medumat vs. MeduVENT ), Continuous positive airway pressure (PEEP 5, AF 10/min, ASB 10) and Chest Compression Synchronized Ventilation (pInsp = 30 vs. 60 mbar; respiratory rate = chest compression rate, PEEP 5) with regard to achieving a sufficient tidal volume and the tightness of various supraglottic airway devices (laryngeal mask, i-Gel-laryngeal mask, laryngeal tube) and endotracheal intubation.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

more than 18 years of age

Disqualifiers

Adult respiratory distress syndrome (ARDS)

Severe lung or thoracic injuries

Pneumothorax

Abnormal airways

Trial design

Design model

Crossover

Treatments tested in this trial

  • treatment

    Other intervention

    * Endotracheal Tube Ventilation with an endotracheal tub * Laryngeal tube Ventilation with a laryngeal tube * Laryngeal mask Ventilation with a laryngeal mask * I-Gel-Laryngeal Mask Ventilation with an I-Gel-laryngeal mask

Treatment groups

3 Participants
are divided into 3 treatment groups
Group A: BIPAP (Bi-Level positive airway pressure)Active comparator 1 intervention
Group B: CPAP ASB (continouos positive airway pressure with assisted spontaneous breathing)Active comparator 1 intervention
Group C: CCSV (Chest Compression Synchronized Ventilation)Active comparator 1 intervention

Trial outcomes

Primary outcomes

1

gained tidalvolume with different airway devices in BIPAP

mean expiratory volume compared to ideal tidalvolume gained by using different airway devices in BIPAP

Time frame
After beginning of ventilation up to 4 minutes each device
2

gained ventilation volume with different airway devices in CPAP-ASB

mean ventilation volume compared to ideal ventilation volume gained by using different airway devices in CPAP-ASB

Time frame
After beginning of ventilation up to 4 minutes each device
3

occurred ventilation pressure with different airway devices in CCSV

mean ventilation pressure needed to develope a sufficient tidalvolume by using different airway devices in CCSV

Time frame
After beginning of ventilation up to 4 minutes each device

Secondary outcomes

1

Mean peak pressure

Mean peak pressure during ventilation

Time frame
After beginning of ventilation up to 4 minutes each device
2

Inspiratory pressure

Inspiratory pressure during ventilation

Time frame
After beginning of ventilation up to 4 minutes each device
3

Peak pressure

Peak pressure during ventilation

Time frame
After beginning of ventilation up to 4 minutes each device
4

Leakage volume

Leakage volume during ventilation

Time frame
After beginning of ventilation up to 4 minutes each device

Other outcomes