Intraoperative Use of I.V. Sodium Fluorescein in Suspected CNS Tumors

ConditionCNS
Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
AgeNot listed
SponsorFondazione I.R.C.C.S. Istituto Neurologico Carlo Besta

About this trial

The FLUO.CER.TUM study is a prospective observational clinical trial conducted at the IRCCS Foundation Neurological Institute "Carlo Besta" in Milan, Italy. It investigates the intraoperative use of intravenous sodium fluorescein as a fluorescent tracer to assist in the surgical resection of suspected malignant tumors of the central nervous system (CNS). These tumors typically present as contrast-enhancing masses on pre-operative MRI or CT scans.

Malignant brain tumors are notoriously difficult to fully resect due to challenges in distinguishing tumor margins from healthy tissue. Sodium fluorescein, a dye that accumulates in areas where the blood-brain barrier is disrupted, offers a promising solution by enhancing tumor visualization during surgery. When used with a dedicated surgical microscope equipped with a fluorescence filter, fluorescein can help surgeons identify and remove more tumor tissue, potentially improving patient outcomes.

The study aims to evaluate the effectiveness and safety of fluorescein-guided surgery in a real-world clinical setting. Approximately 800 patients of any age and gender, with suspected aggressive CNS lesions, will be enrolled. Each patient will receive 5 mg/kg of sodium fluorescein intravenously at the induction of anesthesia. Surgery will be performed using fluorescence-guided techniques, and patients will undergo pre- and post-operative imaging to assess the extent of resection. Clinical and neurological evaluations will also be conducted to monitor outcomes and any adverse effects.

The primary objective is to qualitatively assess the intraoperative fluorescence characteristics of CNS tumors. Secondary objectives include measuring the extent of tumor resection, evaluating post-operative neurological function, and documenting any side effects related to fluorescein administration.

The study adheres to ethical standards, including informed consent and approval by an ethics committee, and will be conducted in accordance with Good Clinical Practice guidelines and the Declaration of Helsinki. Data will be anonymized and securely stored, with results potentially published following appropriate review and approval.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients of both genders, at any age.

Patients with suspected aggressive lesion of the CNS, as suggested by pre-operative MRI or CT with i.v. contrast agent administration.

Disqualifiers

Impossibility to give consent due to cognitive deficits or language disorder.

Known allergy to contrast agents and/or history of previous anaphylactic shocks.

Known severe previous adverse reactions to Fluorescein

Acute myocardial infarction or stroke in the last 90 days.

Trial population

Patients of both genders, at any age.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

No trial groups listed

Trial outcomes

Primary outcomes

1

Intraoperative Fluorescence Characteristics: Fluorescence Intensity of CNS Tumors

Fluorescence intensity of aggressive CNS tumors during surgery using sodium fluorescein and a dedicated surgical microscope. Metric: Visual intensity of fluorescence in relation to tumor margins (measured on a standardized scale).

Time frame
During surgical procedure
2

Intraoperative Fluorescence Characteristics: Fluorescence Distribution of CNS Tumors

Fluorescence distribution of aggressive CNS tumors during surgery using sodium fluorescein and a dedicated surgical microscope. Metric: Spatial distribution of fluorescence relative to tumor margins (e.g., focal vs. diffuse)

Time frame
During surgery
3

Intraoperative Fluorescence Characteristics: Fluorescence Clarity of CNS Tumors

Fluorescence clarity of aggressive CNS tumors during surgery using sodium fluorescein and a dedicated surgical microscope. Metric: Sharpness/definition of fluorescence edges in relation to tumor margins (scored visually)

Time frame
During surgery

Secondary outcomes

1

Extent of Tumor Resection

Quantitative evaluation of the percentage of tumor removed, based on early post-operative MRI or CT with contrast. Metric: Volume of residual tumor compared to pre-operative imaging.

Time frame
Within 72 hours post-surgery
2

Post-operative Neurological Function

Description: Assessment of neurological status following surgery, including motor, sensory, and cognitive functions. Metric: Standard neurological examination scores.

Time frame
Within 72 hours post-surgery
3

Adverse Reactions to Fluorescein

Monitoring and documentation of any side effects or adverse events related to the administration of sodium fluorescein. Metric: Incidence and severity of adverse events (e.g., allergic reactions, renal/hepatic changes)

Time frame
Up to 3 days post-surgery

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.