Intrapartum Ultrasound for Assessment of Fetal Progression

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexFemale
Age18+
SponsorUniversity of Padova

About this trial

The use of ultrasound has been suggested to support the management of labour. According to several studies, ultrasound examination is more accurate and reproducible than clinical examination in diagnosing fetal head position, fetal station, and the prediction of labour arrest. Furthermore, there is growing evidence that ultrasound in labour may predict the outcome of instrumental vaginal delivery: a support to assess when an operative delivery is necessary. Ultrasound in labour can be performed using a transabdominal approach, mainly to determine head and spine position, or a transperineal approach, to assess head station and the situation at low stations. Several sonographic parameters have been proposed to evaluate the head station.

Furthermore, all ultrasound parameters studied so far, have always been measured with the woman in a supine position. While the biomechanics of childbirth with its mechanisms (known as nutation, counter-nutation of the pelvis, and the coccyx retropulsion) together with maternal movement, promote fetal rotation and the adaptation of its diameters with those of the maternal pelvis, allowing to gain more room for the fetal descent. Moreover, in most of the studies on intrapartum ultrasound, the mobility of the pelvis has not been mentioned. The contracted pelvis is the absence of mobility that leads to fetal-pelvic disproportion, arrest of labour, and operative delivery. Maternal pelvis biomechanics studies by high technological techniques have shown that maternal shifting positions during pregnancy and childbirth can create more room in the pelvis for safe delivery. The external and internal pelvic diameters are closely related.

For this reason, the evaluation of the mobility of the pelvis appears to be a necessary element to understand the ability of that pelvis to widen its diameters for fetal descent.

The aim of the study is to measure the variation of AoP for Anterior and trasversal occipital position) or HPD, (in case of occipital posterior head position), in the supine position and kneeling-squat position in the same woman, to identify a significant variation in the two positions.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

pregnant women with singleton pregnancies

at term gestation (37 weeks)

fetus in cephalic presentation

absence of factors hindering vaginal delivery

Disqualifiers

Trial Of Labor After Cesarean (TOLAC)

Vaginal Birth After Cesarean (VBAC);

Twin pregnancies;

Threatened preterm labor (TPL);

Trial design

Design model

Single group

Treatments tested in this trial

  • Transperineal imaging

    Other intervention

    To measure the difference in ultrasound parameters based on maternal position, in particular the variation in the Angle of Progression (AoP) or Head-Perineum Distance (HPD) in the supine and kneeling-squat positions in the same woman during the active second stage of labor, both at rest and during pushing.

Treatment groups

105 Participants
are divided into 1 treatment group
Group A: Transperineal ultrasound during expulsion phase in randomized sequenze maternal positionExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Ultrasound AoP (second stage)

To measure the variation of AOP (Angle of Progression Delta) expressed in degrees, by transperineale ultrasound in the supine position and kneeling squat position in the same woman both at rest and during the pushing . The outcome will be calculated as the within-participant difference in AoP between the two maternal positions.

Time frame
At the beginning of the expulsion phase: ideally within 10 minutes of full cervical dilation and the onset of the urge to push in nulliparous women, and as early as possible -preferably at the onset of the urge to push in multiparous women.
2

Ultrasound HPD (second stage, only in case of occipital posterior head position)

To measure the variation of HPD (Head Perineum Distance Delta) expressed in millimeters, in the supine position and kneeling squat position in the same woman both at rest and during the pushing ( only in case of occipital posterior head position) The outcome will be calculated as the within-participant difference in AoP between the two maternal positions.

Time frame
At the beginning of the expulsion phase: ideally within 10 minutes of full cervical dilation and the onset of the urge to push in nulliparous women, and as early as possible -preferably at the onset of the urge to push in multiparous women.

Secondary outcomes

1

mode of delivery

mode of delivery

Time frame
during delivery, collected after delivery, within 48 hours
2

duration of labour stages

duration of labour stages up to 18 hours

Time frame
during labour stages, collected after delivery, within 48 hours
3

Midwifery interventions during labour

Midwifery interventions during labour

Time frame
during labour (hours), collected immediately after intervention, within 48 hours from delivery
4

Variation in the anteroposterior diameter of the levator hiatus (recruitment phase)

Variation in the anteroposterior diameter of the levator hiatus in spontaneous pushing and Valsalva maneuver in supine and kneeling squat position in the same woman

Time frame
during recruitment, after obtaining verbal consent the participants will undergo a brief trial of the trans-perineal ultrasound so they can become familiar with the procedure

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

University of Padova

Lead sponsor

Azienda Ospedaliera di Padova

Collaborator

This trial is not recruiting at the moment. You can still explore other options: