About this trial
This study will test whether adding knife movement training to standard endoscopic submucosal dissection (ESD) training helps endoscopists perform the procedure faster in a simulation. The added training focuses on how endoscopists move the knife through the endoscope while cutting tissue.
The study plans to enroll 80 endoscopists who have performed 20 to 100 ESD procedures. Participants will be assigned by chance to one of two groups. One group will receive standard ESD training plus knife movement training. The other group will receive standard ESD training alone. Both groups will have one month to practice after training.
Participants will perform ESD on a pig stomach model before training and again after the practice period. The researchers will compare how much dissection speed changes from the first to the second assessment in each group. All study assessments will use the model, with no procedures performed on patients as part of the study.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Early-career endoscopists newly recruited in 2026 or 2027 through the Huadong Hospital endoscopic submucosal dissection (ESD) training program, referrals from other medical institutions, or professional gastroenterology endoscopy networks.
Have previously performed 20 to 100 ESD procedures.
Are willing to participate and accept random assignment, and have provided written informed consent.
Have completed the baseline assessment before enrollment.
Disqualifiers
None
Trial design
Parallel
Treatments tested in this trial
Standard ESD Training
Other interventionPhysicians in both groups receive standard endoscopic submucosal dissection (ESD) training, including theoretical instruction, technique demonstrations, and review of example videos.
Knife Movement Rate Training
Other interventionPhysicians in the experimental group receive additional knife movement rate (KMR)-specific training, including theoretical instruction on KMR-related techniques, technique demonstrations, and review of example videos.
Locally Constructed ESD Training Simulator
DeviceA locally constructed ESD training simulator with an ex vivo porcine stomach mounted in the apparatus is used for hands-on training and skills assessment in both groups. Physician participants practice mucosal incision, submucosal injection, and submucosal dissection on the mounted stomach. Both groups use the same type of simulator.
Treatment groups
Trial outcomes
Primary outcomes
Change From Baseline in ESD Dissection Speed on an Ex Vivo Porcine Stomach Model
Dissection speed is calculated by dividing the resected specimen area in square millimeters by the protocol-defined dissection time in minutes. Specimen area is estimated as pi times the longest and shortest specimen diameters divided by four. For each participant, the change in dissection speed is calculated as the post-training value minus the baseline value, in mm²/min. The change will be compared between the two training groups.
Secondary outcomes
Change From Baseline in Knife Movement Rate
Knife movement rate is calculated as the number of cuts made by moving the knife within the endoscope channel divided by the total number of cuts classified as knife-moving or knife-stationary, multiplied by 100. Change is calculated as the post-training value minus the baseline value, in percentage points.
Reduction From Baseline in ESD Procedure Time
The reduction in procedure time is calculated as baseline time minus post-training time, in minutes. A positive value indicates a shorter procedure time after training.
Rate of Perforation or Muscular Layer Injury in the Ex Vivo Model
Percentage of model ESD procedures in which perforation, muscular layer injury, or both are observed.
En Bloc Resection Rate in the Ex Vivo Model
Percentage of model ESD procedures in which the target tissue is removed in a single piece.