Leadless Versus Conventional Pacemakers: Effects on Heart Function and Heart Failure

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorKarl Landsteiner University of Health Sciences

About this trial

People with a slow heart rhythm may need a permanent pacemaker. Conventional pacemakers use a device placed under the skin and wires that pass through veins into the heart. Leadless pacemakers are placed directly inside the heart without a chest pocket or these wires. Both approaches can provide pacing, but their effects on heart function and heart-failure-related problems need to be compared.

LEAP-HF will compare an indication-adapted leadless pacemaker strategy with a conventional transvenous pacemaker strategy in 760 adults for whom either approach is clinically appropriate. Participants must have a left ventricular ejection fraction above 40% and must not require a defibrillator, cardiac resynchronization therapy, or chronic atrial pacing. Participants will be assigned by chance, in equal proportions, to the two strategies. The device and pacing mode will be selected according to the participant's clinical indication within the assigned strategy.

The main question is whether the leadless strategy is not unacceptably worse than the conventional strategy for pacing-induced cardiac dysfunction during 12 months of follow-up. This outcome includes a qualifying deterioration in heart pumping function, pacemaker syndrome, heart failure requiring hospitalization, or an upgrade to cardiac resynchronization therapy. The prespecified non-inferiority margin is an absolute difference of 7 percentage points.

Assessments include heart ultrasound, pacemaker checks, an electrocardiogram, a blood test for NT-proBNP, symptom assessment, and questionnaires about health and quality of life. There will be a telephone contact at 6 weeks and in-person visits at 6 and 12 months after implantation. The study will also compare heart function, complications, further procedures, and deaths. Participants and treating teams will know which pacing system was implanted; selected clinical events will be reviewed by an independent committee unaware of the assigned treatment.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 years or older.

Guideline-based indication for permanent ventricular pacing for which both leadless and transvenous strategies are clinically appropriate, such as permanent atrial fibrillation with slow ventricular response, high-degree atrioventricular block, or pacing after atrioventricular junction ablation.

Baseline left ventricular ejection fraction above 40%, assessed within 14 days before implantation and before randomization. Absence of a guideline-based indication for cardiac resynchronization therapy or an implantable cardioverter-defibrillator must be confirmed separately.

No guideline-based requirement for chronic atrial pacing, such as symptomatic sinus node dysfunction requiring an atrial lead.

Disqualifiers

Current guideline-based indication for cardiac resynchronization therapy or an implantable cardioverter-defibrillator, or a requirement for chronic atrial pacing.

Recent myocardial infarction or active myocarditis within 3 months, or another planned cardiac intervention likely to affect left ventricular ejection fraction within 12 months, such as severe valve disease requiring intervention.

Severe right ventricular dysfunction, for example tricuspid annular plane systolic excursion below 12 mm or right ventricular systolic tissue Doppler velocity below 8 cm/s, where advanced right ventricular failure could confound the pacing strategy comparison.

Active systemic infection or endocarditis.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Leadless pacemaker implantation

    Device

    Implantation and indication-adapted programming of a leadless pacemaker system. The current protocol lists Medtronic Micra VR2, Medtronic Micra AV2, Abbott AVEIR VR, and Abbott AVEIR AR/VR dual-chamber systems. The selected system must be appropriate for the clinical indication and permitted by the applicable approvals and study protocol. Follow-up includes standardized device interrogation and assessment of ventricular pacing burden.

  • Conventional transvenous pacemaker implantation

    Device

    Implantation and indication-adapted programming of a conventional transvenous single- or dual-chamber pacemaker with right ventricular pacing. The current protocol lists systems from Abbott, Biotronik, Boston Scientific, Medtronic, and MicroPort/Sorin. Device type and pacing mode are selected according to the prespecified clinical algorithm. Lead position, electrical parameters, programming, and right ventricular pacing burden are documented. Conduction system pacing is not part of the assigned strategy.

Treatment groups

760 Participants
are divided into 2 treatment groups
Group A: Leadless pacing strategyExperimental treatment 1 intervention
Group B: Conventional transvenous pacing strategyActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Cumulative incidence of pacing-induced cardiac dysfunction

Participant-level composite of: (1) LVEF decline of at least 10 percentage points to below 50%, RV pacing burden at least 40%, and no alternative cause; (2) new or worsened symptoms compatible with loss of AV synchrony, reduced AV synchrony, and RV pacing burden at least 40% at the last available interrogation; (3) hospitalization primarily for acute decompensated heart failure requiring IV diuretics and/or vasodilators, with RV pacing burden at least 40%; or (4) CRT upgrade for symptomatic heart failure, LVEF below 50%, and RV pacing burden at least 40%. HF admissions and CRT upgrades use the prespecified interrogation rule and blinded adjudication. Each participant is counted once. Death before PICD is a competing event, not a component. An event at 6 months remains an event at 12 months. LVEF=left ventricular ejection fraction; RV=right ventricular; AV=atrioventricular; CRT=cardiac resynchronization therapy; HF=heart failure; PICD=pacing-induced cardiac dysfunction.

Time frame
Up to 12 months after implantation for clinical events; echocardiographic assessments at 6 and 12 months after implantation (each +/-30 days).

Secondary outcomes

1

Change in left ventricular ejection fraction from baseline to 12 months

Change in left ventricular ejection fraction (LVEF), expressed in percentage points, assessed by standardized independent echocardiographic evaluation. The treatment contrast is leadless minus transvenous. Non-inferiority requires the lower bound of the two-sided 95% confidence interval to exceed -3.5 percentage points. This is the first key secondary test and is confirmatory only after primary non-inferiority has been established. Handling of death and missing assessments will be prespecified in the statistical analysis plan.

Time frame
Baseline (within 14 days before implantation and before randomization) and 12 months after implantation (+/-30 days).
2

NT-proBNP at 12 months adjusted for baseline NT-proBNP

N-terminal pro-B-type natriuretic peptide (NT-proBNP) at 12 months, analysed on the logarithmic scale with adjustment for baseline NT-proBNP. The treatment contrast is the ratio of adjusted geometric means, leadless divided by transvenous. Non-inferiority requires the upper bound of the two-sided 95% confidence interval to be below 1.5. This is the second key secondary test and is confirmatory only if all preceding tests succeed. Handling of death and missing assessments will be prespecified in the statistical analysis plan.

Time frame
Baseline (within 14 days before implantation and before randomization) and 12 months after implantation (+/-30 days)
3

Participants with all-cause death, any heart-failure hospitalization, or urgent pacemaker-related reintervention

Number and percentage of participants with at least one of the following: death from any cause, any heart-failure hospitalization, or urgent pacemaker-related reintervention. Each participant is counted once for the composite. Unlike the primary composite, heart-failure hospitalization in this outcome is not restricted by a right ventricular pacing burden threshold. This is the third key secondary test, assessed for superiority at a two-sided significance level of 0.05 only if all preceding tests succeed; otherwise, the comparison is exploratory.

Time frame
From implantation up to 12 months after implantation.
4

Change in left ventricular ejection fraction from baseline to 6 months

Change in left ventricular ejection fraction, expressed in percentage points, measured by standardized independent echocardiographic evaluation. This analysis is supportive and is not part of the fixed confirmatory testing sequence.

Time frame
Baseline (within 14 days before implantation and before randomization) and 6 months after implantation (+/-30 days).

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: