About this trial
The goal of this clinical study is to learn if the AVEIR CSP Leadless Pacemaker System is safe and works to treat adults with slow heart rhythms or irregular heartbeats. The main questions the study aims to answer are:
What medical problems do participants have after being implanted with the AVEIR CSP System for 3 months?
Does the AVEIR CSP System pace and sense the heart effectively after 3 months?
Participants will be implanted with the AVEIR CSP System and will be asked to return to or call the clinic periodically to report their symptoms. Participants will also complete two short questionnaires describing how their quality of life has changed.
Researchers will adjust the settings of the implanted device through a special programmer, as needed, and will check the participants' heart rhythm through an electrocardiogram. Researchers will also check on the device's implant location using a chest x-ray and evaluate the participants' heart function using an echocardiogram.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Subject must have at least one standard pacemaker indication in adherence with ACC/AHA/HRS/ESC bradycardia pacing guidelines
Subject must be at least 18 years of age or the legal age, whichever age is greater
Subject has life expectancy of at least 2 years
Subject is willing to comply with clinical investigation procedures and agrees to return to clinic or participate in remote visits, as applicable, for all required follow-up visits, tests, and exams
Disqualifiers
Subject has a mechanical tricuspid valve, percutaneous tricuspid valve repair or replacement, or any implanted vena cava filter
Subject has evidence of tricuspid stenosis, tricuspid atresia, or presence of any condition that precludes appropriate vascular access for the study procedure
Subject has pre-existing, permanent endocardial pacing or defibrillation leads or any devices in the right heart or interventricular septum
Subject has an active implantable electronic device that cannot be turned off during the study procedure
Trial design
Single group
Treatments tested in this trial
AVEIR CSP Leadless Pacemaker System
DeviceParticipants will undergo a single or dual-chamber leadless pacemaker system implant wherein an investigational AVEIR CSP leadless pacemaker will be implanted in the right ventricle. Then, a commercial AVEIR AR leadless pacemaker may optionally be co-implanted in the right atrium, if indicated.
Treatment groups
Trial outcomes
Primary outcomes
Percentage of Participants Free From AVEIR CSP-Related Complications at 3 months
AVEIR CSP System complication-free-rate. A complication is defined as an AVEIR CSP LP device or AVEIR CSP LP procedure-related serious adverse event.
Percentage of Participants With Acceptable AVEIR CSP Threshold and Amplitude Measurements at 3 months
Composite success rate of acceptable pacing thresholds and sensing amplitudes of the AVEIR CSP System among implanted participants. A participant was considered to have met the primary effectiveness endpoint if the pacing threshold voltage was ≤ 2.5 V at 0.4 ms at the 3-month visit and the sensed R-wave amplitude was ≥ 3.0 mV or ≥ value at implant at the 3-month visit.
Secondary outcomes
Percentage of Participants Who Survive Through 2 Years
All-Cause Survival Rate through 2 years among participants enrolled in the United States who were successfully implanted with an AVEIR CSP Leadless Pacemaker System