About this trial
The goal of this clinical trial is to learn if LED repeated low-level red light (RLRL) therapy works to treat pathologic myopia in adults. It will also learn about the safety of LED-RLRL. The main questions it aims to answer are:
Does LED-RLRL modulate choroidal microcirculation to retard retinal atrophy in pathological myopia? What medical problems do participants have when receiving LED-RLRL therapy? Researchers will compare with a sham device (identical in appearance but delivering \<10% of the original device's energy output) to see if LED-RLRL works to treat pathologic myopia.
Participants will:
Take LED-RLRL or sham LED-RLRL twice daily, 3 minutes per session, 5 days per week, for a total duration of 12 months.
Visit the clinic once every 3 months for checkups and tests. Keep a diary of their symptoms and their visual perception.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age range: 18 to 55 years old;
Baseline visual acuity: Best Corrected Visual Acuity (BCVA) ≥ 0.1 (LogMAR ≤ 1.0);
Meeting the diagnostic criteria for high myopia: Spherical Equivalent (SE) ≤ -6.00 D and Axial Length (AL) ≥ 26.0 mm;
Disqualifiers
Concurrent with other ophthalmic diseases that may affect visual acuity or outcome assessment, including active myopic choroidal neovascularization (CNV) requiring anti-VEGF therapy, macular hole, vitreous hemorrhage, diabetic retinopathy, retinal detachment, retinal vein occlusion, optic neuritis, uveitis, severe cataract, and glaucoma;
Systemic contraindications: Photosensitive epilepsy, autoimmune diseases (e.g., systemic lupus erythematosus), or pregnant/lactating women; Patients who have undergone intraocular surgery, laser treatment, or ophthalmic medication therapy within 3 months prior to enrollment;
Patients unable to comply with regular follow-up (e.g., due to remote residence) or with cognitive impairment;
Opaque refractive media that hinder fundus examination.
Trial design
Parallel
Treatments tested in this trial
LED red light
DeviceAn LED-RLRL device (Airdoc PBM-LED, Model No.: AI-PBM01, Beijing Airdoc Technology Co., Ltd.) was adopted. It has a working wavelength of 650 nm, with an output power of 1.39 mW at the light source, and the output power is 1.39 mW ± 0.1 mW at a position 30 mm away from the observation window glass. Twice daily, 3 minutes per session, 5 days per week, for a total duration of 12 months.
Sham LED red light
DeviceA sham LED-RLRL device (identical in appearance but delivering \<10% of the original device's energy output) . Twice daily, 3 minutes per session, 5 days per week, for a total duration of 12 months.
Treatment groups
Trial outcomes
Primary outcomes
Choroidal vascular density
Choroidal vessel volume index
Secondary outcomes
Choroidal thickness
Distance between Bruch's membrane and choroidal-scleral interface
Retinal thickness
Retinal vascular density
Other outcomes
Changes in BCVA
best-corrected visual acuity
Incidence of allergic reactions
including photophobia, blurred near vision, afterimage, elevated IOP, headache, nausea, and vomiting
Changes in AL
axial length
Changes in SE
spherical equivalent
Sponsors and contacts
Click on the lead sponsor to view all of their trials.