Listening Volume Adjustment in Bone and Air Conduction Headphones

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-35
SponsorSecond Affiliated Hospital, Zhejiang University, School of Medicine

About this trial

Open-ear bone conduction headphones are increasingly used as an alternative to conventional in-ear air conduction headphones. Because bone conduction headphones do not block the ear canal, it is often assumed that users may be more affected by background noise and may increase their listening volume to hear music clearly. However, direct evidence supporting this assumption is limited.

This study aims to compare self-adjusted listening volumes between bone conduction and air conduction headphones under different background noise conditions. Approximately 32 healthy adults aged 18-35 years with normal hearing will participate in the study. Each participant will test three listening conditions: in-ear air conduction headphones, open-ear bone conduction headphones, and bone conduction headphones combined with ear occlusion. Each condition will be tested in a quiet environment and under four levels of background noise (30, 40, 50, and 60 dB(A)).

Participants will listen to the same music and adjust the volume themselves to a level they consider comfortable and clear for prolonged listening. The selected listening volume and adjustment behavior will be recorded and compared across headphone types and noise conditions.

The findings may provide behavioral evidence on whether open-ear bone conduction headphone users choose higher listening volumes in noisy environments compared with users of conventional in-ear air conduction headphones, helping to improve understanding of potential noise exposure and hearing safety.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Age 18-35 years.

Type A, As, or Ad tympanogram in both ears.

Normal hearing in both ears, defined as pure-tone hearing thresholds of ≤20 dB HL at each of the following frequencies: 0.25, 0.5, 1, 2, 4, and 8 kHz.

Willingness to participate and ability to understand and provide written informed consent.

Disqualifiers

History of prolonged exposure to high-intensity noise.

History of prolonged use of ototoxic medications.

History of otologic diseases resulting in permanent changes in hearing thresholds.

Previous diagnosis of hereditary hearing loss or a definite family history of 5. hearing loss.

Trial design

Design model

Crossover

Treatments tested in this trial

  • In-ear Air Conduction Headphones

    Behavioral

    Participants will wear in-ear air conduction headphones and independently adjust the music volume to a level they consider comfortable and clear for prolonged listening. Testing will be conducted in a quiet environment and under background noise levels of 30, 40, 50, and 60 dB(A). The final selected volume and adjustment behavior will be recorded.

  • Open-ear Bone Conduction Headphones

    Behavioral

    Participants will wear open-ear bone conduction headphones and independently adjust the music volume to a level they consider comfortable and clear for prolonged listening. Testing will be conducted in a quiet environment and under background noise levels of 30, 40, 50, and 60 dB(A). The final selected volume and adjustment behavior will be recorded.

  • Bone Conduction Headphones with Ear Occlusion

    Behavioral

    Participants will wear open-ear bone conduction headphones while simultaneously inserting in-ear air conduction headphones into both ear canals to create an ear occlusion condition. Music will be delivered exclusively through the bone conduction headphones. Participants will independently adjust the music volume to a level they consider comfortable and clear for prolonged listening. Testing will be conducted in a quiet environment and under background noise levels of 30, 40, 50, and 60 dB(A). The final selected volume and adjustment behavior will be recorded.

Treatment groups

32 Participants
are divided into 2 treatment groups
Group A: AC-BCExperimental treatment 3 interventions
Group B: BC-ACExperimental treatment 3 interventions

Trial outcomes

Primary outcomes

1

Change in Self-Adjusted Listening Volume From Quiet to 60 dB(A) Background Noise Levels

The change in final self-adjusted music volume from the quiet condition to the 60 dB(A) background noise condition will be calculated separately for each headphone condition (in-ear air conduction headphones \[AC\] and open-ear bone conduction headphones \[BC\]). The change will be calculated as the final volume at 60 dB(A) minus the final volume in the quiet condition. The differences in volume change among the two headphone conditions will be compared.

Time frame
During the study visit (approximately 1-2 hours).

Secondary outcomes

1

Change in Self-Adjusted Listening Volume From Quiet to 30, 40, and 50 dB(A) Background Noise Levels

The change in final self-adjusted music volume from the quiet condition to each background noise level (30, 40, and 50 dB(A)) will be calculated separately for in-ear air conduction headphones (AC) and open-ear bone conduction headphones (BC). The change will be calculated as the final volume at each noise level minus the final volume in the quiet condition. The volume changes between the two headphone conditions will be compared at each noise level.

Time frame
During the study visit (approximately 1-2 hours).
2

Final Self-Adjusted Listening Volume at Different Background Noise Levels

The final self-adjusted music volume at quiet condition, 30, 40, 50, and 60 dB(A) background noise levels will be recorded and compared between AC and BC headphones.

Time frame
During the study visit (approximately 1-2 hours).
3

Number of Volume Adjustments

The total number of individual volume adjustments made by each participant during each test will be recorded and compared between AC and BC headphones under different background noise conditions.

Time frame
During the study visit (approximately 1-2 hours).
4

Total Time Required for Volume Adjustment

The total time from the beginning of volume adjustment to reaching the final self-adjusted listening volume will be recorded and compared between AC and BC headphones under different background noise conditions.

Time frame
During the study visit (approximately 1-2 hours).

Other outcomes

1

Change in Self-Adjusted Listening Volume With Ear Occlusion During Bone Conduction Listening

The change in final self-adjusted music volume from the quiet condition to each background noise condition (30, 40, 50, and 60 dB(A)) will be calculated when participants use bone conduction headphones with bilateral ear occlusion (BC+Occlusion). The results will be compared with those obtained using bone conduction headphones without ear occlusion (BC) to evaluate the effect of ear occlusion on noise-induced volume adjustment.

Time frame
During the study visit (approximately 1-2 hours).
2

Final Self-Adjusted Listening Volume With Ear Occlusion During Bone Conduction Listening

The final self-adjusted music volume under quiet and background noise conditions (30, 40, 50, and 60 dB(A)) will be recorded during bone conduction headphone use with bilateral ear occlusion (BC+Occlusion) and compared with the corresponding BC condition without ear occlusion.

Time frame
Time Frame: During the study visit (approximately 1-2 hours).

Sponsors and contacts

Click on the lead sponsor to view all of their trials.