Locally Optimised Contouring With AI Technology for Radiotherapy

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorRoyal North Shore Hospital

About this trial

LOCATOR is a multicentre phase II randomised clinical trial that is looking at the process of contouring in radiation treatment for breast cancer patients. This study looks at whether contouring aided by artificial intelligence (AI) is comparable in quality to that of contouring done completely manually by a radiation oncologist. We are also looking at whether AI assisted contouring saves radiation oncologists time when compared to fully manual contouring.

LOCATOR uses the LOCATOR software which is an in-house software developed locally and trained on local data.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

18 years and older who are planned for primary breast malignancy

ECOG performance 0-2

Ability to understand and willingness to sign a written informed consent document

The target volume must be able to be objectively reviewed by current published national or international clinical guidelines

Disqualifiers

Patients under 18 years of age

Patients unable to understand consent documents

Trial design

Design model

Parallel

Treatments tested in this trial

  • AI assisted contouring

    Device

    Initial are generated automatically using software powered by artificial intelligence

Treatment groups

444 Participants
are divided into 2 treatment groups
Group A: AI assisted contouringExperimental treatment 1 intervention
Group B: Manual contouringNo intervention 0 interventions

Trial outcomes

Primary outcomes

1

Assessment of differences in Contour Quality

To assess the contour quality of fully manual segmentation vs AI assisted segmentation. This assessment will be done using the MD Anderson Cancer Centre five-point likert scale used to validate autosegmentation models ranging from (Strongly disagree to Strongly Agree). The measure will be the proportion of unacceptable contours (as defined by MD Anderson autocontouring score \<= 2) between manual contouring and AI-assisted contouring.

Time frame
18 months

Secondary outcomes

1

Assessment of quality of AI assisted contours with and without manual edits

To assess the contour quality of AI assisted contours with and without manual edits. This assessment will be done using the MD Anderson Cancer Centre five-point likert scale used to validate autosegmentation models ranging from (Strongly disagree to Strongly Agree). The measure will be the proportion of unacceptable contours (as defined by MD Anderson autocontouring score \<= 2) between manual contouring and AI-assisted contouring.

Time frame
18 months
2

Time Savings

To evaluate the difference in time taken to contour with and without the assistance of an auto-segmentation tool.

Time frame
18 months
3

To assess the differences in acute clinician reported toxicity between patients treated with contours assisted by AI contouring versus manual contouring.

Acute clinician reported toxicity will be measured using CTCAE version 5.0 across individual items (see full protocol appendix). For this study, the outcome will be the difference in the proportion of patients with grade≥3 toxicity at any point in time from the start of radiotherapy to 90 days following radiotherapy.

Time frame
18 months
4

To assess the differences in late clinician reported toxicity between patients treated with contours assisted by AI contouring versus manual contouring.

Late clinician reported toxicity will be measured using CTCAE version 5.0 across individual items (see full protocol appendix). For this study, the outcome will be the difference in the proportion of patients with grade≥3 toxicity at any point in time between 90 days following radiotherapy and 5 years following radiotherapy.

Time frame
5 years

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.