About this trial
The goal of this retrospective study is to evaluate the clinical characteristics, efficiency, safety, and long-term performance of craniomaxillofacial (CMF) Porous Titanium Implants within the standard of care across children (0 - \<12 years old), adolescent (12 - \<22 years old), and adult (≥ 22 years old) populations.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age: Patients of any age are eligible for this study.
Patients treated with Materialise patient-specific CMF Porous Titanium Implants for facial and/or cranial reconstruction.
Patients who have followed Standard of Care, as determined in each case by the treating surgeon.
Disqualifiers
Known hypersensitivity to Titanium at the time of surgery.
Patients who had or will receive the TMJ Total Arthroplasty System.
Pregnancy at the time of surgery.
Trial population
Retrospective collection of a minimum of 200 patients that were treated between 2016 and 2023 with patient-specific CMF Porous Titanium Implants for facial and/or cranial reconstruction or restoration of bone defects. All patients included in the study underwent standard visits and follow-up assessments in-hospital.
Trial design
Cohort
Retrospective
Treatments tested in this trial
Craniomaxillofacial (CMF) porous titanium implant
DeviceAll patients were treated, between 2016 and 2023, with patient-specific CMF Porous Titanium Implants for facial and/or cranial reconstruction or restoration of bone defects.
Treatment groups
Trial outcomes
Primary outcomes
Last visit success rate of the device after the surgical implantation of Materialise patient-specific CMF Porous Titanium Implants
Success is defined as follows: \- The device is securely in place and functional as of the last follow-up or until its removal for reasons unrelated to the device itself. Failure is defined as follows: * Reoperation without device removal related to the device. * Reoperation with device removal related to the device.
Secondary outcomes
Perioperative complications related and unrelated to CMF Porous Titanium Implants
Complications related and unrelated to CMF Porous Titanium Implants, including allergic reaction to the anesthetic or titanium (anaphylaxis), complications related to the anesthesia, hematoma, or others.
General post-operative complications up to standard of care (SOC) follow-up
Complications related and unrelated to CMF Porous Titanium Implants, including infection, pain, implant migration, implant exposure, failure of implant, device subsidence, device fracture, diplopia, hematoma, dysesthesia, osteolysis, fistula, wound dehiscence, delayed healing, or others.
Re-intervention rate, implant-related or not
Intraoperative blood loss (mL)
Estimated blood loss by visual inspection or gravimetric method
Sponsors and contacts
Click on the lead sponsor to view all of their trials.