Lumoptik BRIGHTPOINT Reflectometer Device for Lumbar Epidural Placement

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-99
SponsorHospital for Special Surgery, New York

About this trial

The goal of this clinical trial is to test the BrightPoint Epidural device as the first system to use multispectral reflectometry to find the epidural space in lumbar neuraxial procedures requiring epidural needle. The main questions it aims to answer are:

1. Is the device a qualitatively effective secondary confirmation of Loss of Resistance? 2. Is the device a qualitatively effective training tool for educating trainees in how to perform lumbar epidurals?

Participants will undergo a neuraxial procedure in which the attending anesthesiologist will use the BrightPoint epidural device to form an opinion on its effectiveness in confirming epidural space access.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Any patient undergoing a lumbar neuraxial procedure requiring epidural needle

Age 18-99

Disqualifiers

Previous lumbar spine surgery

Any known spinal abnormality that would interfere with successfully advancing a needle into the epidural space

Any patient requiring epidural needle longer than 4 inches

Any contraindication to neuraxial anesthesia

Trial population

Patients scheduled to have surgery at the Hospital for Special Surgery that will require a lumbar neuraxial procedure requiring an epidural needle.

Trial design

Design model

Other

Time perspective

Prospective

Treatments tested in this trial

  • Group 1 - Lumoptik BrightPoint Epidural Device

    Device

    Participants will undergo a neuraxial procedure to measure loss of resistance with saline in conjunction with the Lumoptik BrightPoint Epidural Device.

Treatment groups

36 Participants
are divided into 1 treatment group
Group A: Group 11 intervention

Trial outcomes

Primary outcomes

1

Real time confirmation of epidural space with loss of resistance technique

On the post-procedure questionnaire, the anesthesiologist will report about whether the device identified epidural space in agreement with loss of resistance technique. If no, the outcome will be recorded as either a false positive (device signaled epidural space while needle was not in epidural space) or false negative (device did not signal epidural space while needle was in epidural space).

Time frame
Post-operation (after the surgery is complete)

Secondary outcomes

1

Clinical (anesthesiologist) opinions on Lumoptik Bright Point Epidural device

On the post-procedure questionnaire, the anesthesiologist will give their opinion about the device following their use of the study device.

Time frame
Post-operation (after the surgery is complete)
2

Color graphics aid in the identification of needle tips.

On the post-procedure questionnaire, the proceduralist will give a yes or no answer to the prompt to the question "Did the Bright Point Epidural color graphic improve your understanding of where your needle tip is or what tissue it is in?"

Time frame
Post-operation (after the surgery is complete)
3

The time it takes to insert the epidural needle into the patient's skin.

The time between when the patient entered the operating room and when the epidural needle was inserted into the patient's skin.

Time frame
From "in OR time" to "time when needle is inserted"
4

The time it takes to successfully identify the epidural space.

The time between inserting an epidural needle into the skin and successfully identifying the epidural space.

Time frame
From "time when needle is inserted" to "time when epidural space is identified"

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.