Measurement of Expiratory Gas Temperature in Intubated Patients to Estimate Expiratory Absolute Humidity

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorLaval University

About this trial

Adequate humidification is essential for intubated patients because dry medical gases can cause thick secretions and dangerous endotracheal tube blockages. A clear correlation exists between exhaled and inhaled humidity delivered by heat and moisture exchanger. The objective of this study is to measure the temperature of exhaled gases in intubated patients in order to accurately calculate the absolute humidity during the expiratory phase. These data will allow for a more accurate reproduction of real clinical conditions during bench testing and will improve the assessment of heat and moisture exchanger performance device evaluation.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adults (≥18 years)

Intubated and mechanically ventilated in the intensive care unite

Using passive humidification (Heat and Moisture exchanger)

Disqualifiers

PEEP set < 12 cmH₂O

Inhaled nitric oxide therapy

Tracheostomy

Trial population

Intubated patient using a heater and moist exchanger

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Expiratory gases temperature

    Other intervention

    Measure expiratory gas temperature immediately before the passive humidifier in intubated ICU patients and evaluate the relationship between body temperature and expiratory temperature.

Treatment groups

70 Participants
are divided into 3 treatment groups
Group A: Normothermic patient1 intervention
Group B: Hypothermic patient1 intervention
Group C: Hyperthermic patient1 intervention

Trial outcomes

Primary outcomes

1

Expiratory gas temperature

Measure expiratory gas temperature immediately before the passive humidifier

Time frame
H0, up to 60 minutes after inclusion
2

Relationship between body temperature and expiratory temperature.

Evaluate the relationship between body temperature and expiratory temperature

Time frame
H0, up to 60 minutes after inclusion

Secondary outcomes

1

Estimate expiratory absolute humidity based on measured temperature

Time frame
H0, up to 60 minutes after inclusion