About this trial
This study aims to evaluate the effect of hepatic ultrasound treatment on changes from baseline in whole-body insulin sensitivity during a hyperinsulinemic, euglycemic clamp (HE Clamp).
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Type 2 diabetic (T2D) subjects must be aged 18-80 and must be able to provide written informed consent
All subjects must have had T2D for at least 3 months prior to study enrollment. All subjects must be either on diet and exercise or oral antidiabetic agents alone, not on insulin or any form of insulin or GLP-1 receptor agonists.
A fasting plasma glucose (FPG) level of 126 mg/dL (7.0 mmol/L) or higher, or
A 2-hour plasma glucose level of 200 mg/dL (11.1 mmol/L) or higher during a 75-g oral glucose tolerance test (OGTT), or
Disqualifiers
BMI >40kg/m2.
Untreated proliferative retinopathy
Creatinine clearance < 60 ml/min/1.73 m2.
Serum creatinine ≥1.5 mg/dL
Trial design
Parallel
Treatments tested in this trial
Ultrasound
DeviceThe General Electric LOGIQ E10 ultrasound pulsed doppler imaging system and C1-6-D XDclear abdominal curvilinear probe will be used to administer ultrasound.
OGTT with unlabeled glucose and liver NMR
Diagnostic testSubjects will undergo an OGTT with unlabeled glucose to measure liver glycogen concentration by NMR spectroscopy.
OGTT with carbon-13 labeled glucose and liver NMR
Diagnostic testSubjects will undergo an OGTT with carbon-13 labeled glucose to measure liver glycogen synthesis rate by NMR spectroscopy.
CGM glucose reading
Diagnostic testA continuous glucose monitor (CGM) will be collecting glucose level changes over a 10-14day time period after the ultrasound.
HEC - Hyperinsulinemic-Euglycemic-Clamp
Diagnostic testA constant i.v. insulin and variable glucose infusion will be used to determine insulin sensitivity of study participants.
Treatment groups
Trial outcomes
Primary outcomes
Insulin Sensitivity
Insulin Sensitivity calculated as Glucose disposal rate / insulin ratio during steady state (M/I) to evaluate the effect of hepatic ultrasound treatment on changes from baseline in whole-body insulin sensitivity during a hyperinsulinemic, euglycemic clamp (HE Clamp)
Glucose disposal rate
Glucose disposal rate during steady state (M) to evaluate the effect of hepatic ultrasound treatment on changes from baseline in whole-body insulin sensitivity during a hyperinsulinemic, euglycemic clamp (HE Clamp)
Glucose metabolic clearance rate
Glucose metabolic clearance rate during steady state (MCR) to evaluate the effect of hepatic ultrasound treatment on changes from baseline in whole-body insulin sensitivity during a hyperinsulinemic, euglycemic clamp (HE Clamp)
Secondary outcomes
Absolute glycogen level
The effect of hepatic plexus-directed pFUS on absolute glycogen level by observing the metabolic fate of unlabeled glucose ingested during oral glucose tolerance testing measured by 13C liver NMR-spectroscopy.
Glycogen synthesis rates
Glycogen synthesis rates are derived from plasma 13C -glucose levels achieved during the OGTT and subsequent appearance of 13C -tracer in liver glycogen
Change from baseline in blood glucose (BG) time spent in defined glucose ranges
Change from baseline in blood glucose (BG) time spent in defined glucose ranges assessed using a continuous glucose monitoring system (CGMS)
Average daily glucose
Average daily glucose assessed using a continuous glucose monitoring system (CGMS)
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Yale University
Lead sponsor
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Collaborator