Mi2000 TICI Follow-up

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorMED-EL Elektromedizinische Geräte GmbH

About this trial

This Post-Market Clinical Follow-up (PMCF) investigation aims to further collect evidence on safety and performance of the Mi2000 TICI. This PMCF investigation will collect retrospective and prospective clinical data from the use of the Mi2000 TICI and related devices.

This PMCF investigation is performed on a new cochlear implant system, which was previously studied in two pre-market clinical investigations with limited follow-up duration. The purpose of the current clinical investigation is to collect further evidence by collecting clinical data on the use of the Mi2000 TICI.

The Mi2000 TICI is a state-of-the-art cochlear implant, designed to be totally implantable, indicated to treat severe to profound hearing loss, asymmetric hearing loss and single-sided deafness.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Recipient of an Mi2000 TICI in one of the pre-market studies

Signed and dated informed consent before the start of any study-specific procedure

Disqualifiers

Lack of compliance with any inclusion criterion

Anything that, in the opinion of the Investigator, would

place the subject at increased risk

preclude the subject's full compliance with or completion of the study

Trial population

This clinical investigation aims to enrol participants of previous clinical investigations, implanted with the Mi2000 TICI UNICO.

Trial design

Design model

Cohort

Time perspective

Other

Treatments tested in this trial

  • Cochlear Implantation

    Device

    Participants in this clinical investigation received a totally implantable cochlear implant and will be followed-up for an extended period of time.

Treatment groups

36 Participants
are divided into 1 treatment group
Group A: Mi2000 TICI UNICO recipients1 intervention

Trial outcomes

Primary outcomes

1

Word Test in Quiet

Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes

Time frame
Pre-op to 36 months after first fitting

Secondary outcomes

1

Nijmegen Cochlear Implant Questionnaire (NCIQ)

Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes

Time frame
Pre-op to 36 months after first fitting
2

Speech, Spatial, Quality of Hearing (SSQ12)

Speech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes

Time frame
Pre-op to 36 months after first fitting

Other outcomes

1

Word test in quiet

Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes

Time frame
through study completion, an average of 60 months after first fitting
2

Sentence Test in Noise

Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes

Time frame
through study completion, an average of 60 months after first fitting
3

Health Utility Index Mark 3 (HUI3)

Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death.

Time frame
through study completion, an average of 60 months after first fitting
4

Nijmegen Cochlear Implant Questionnaire (NCIQ)

Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes

Time frame
through study completion, an average of 60 months after first fitting

Sponsors and contacts

Click on the lead sponsor to view all of their trials.