About this trial
The goals of this observational study are to develop and train artificial intelligence (AI) algorithms using multimodal imaging to identify patients with inherited retinal degeneration (IRD) caused by Retinal Pigment Epithelium Specific Protein 65 (RPE65) and Retinitis Pigmentosa GTPase Regulator (RPGR) mutations. Another algorithm will be developed to measure and monitor retinal changes over time, with the aim of helping identify patients who may be suitable for available or emerging treatments and supporting assessment of disease progression and treatment response.
The main questions this study aims to answer are:
1. Can AI algorithms accurately distinguish patients with RPE65- or RPGR-associated IRDs from individuals without these conditions using ultra-widefield retinal imaging? 2. Can AI algorithms accurately detect and quantify retinal abnormalities associated with these conditions and monitor their progression over time on ultra-widefield retinal imaging?
Researchers will compare retinal images from patients with RPE65- or RPGR-associated IRDs with images from healthy participants, including people with and without myopia, to assess how accurately the algorithms can distinguish between these groups and monitor disease-related changes.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Retinal Pigment Epithelium Specific Protein 65 (RPE65)-associated retinal degeneration: genetically confirmed biallelic sequence variants in RPE65.
Participants with a clinical diagnosis of Leber congenital amaurosis or early onset severe retinal degeneration whose phenotype is suggestive of biallelic RPE65-associated retinal degeneration will also be eligible for inclusion.
Retinitis Pigmentosa GTPase Regulator (RPGR)-associated retinal degeneration: genetically confirmed hemizygous RPGR sequence variants in male participants, or female participants with single heterozygous RPGR sequence variants or homozygous or compound heterozygous RPGR sequence variants will be included in this cohort.
Participants with a clinical diagnosis of X-linked Retinitis Pigmentosa and X-linked cone-rod degeneration whose phenotype is suggestive of RPGR-associated retinal degeneration will also be eligible for inclusion.
Disqualifiers
Participants who do not meet the clinical, genetic, or control-group criteria for any of the predefined study cohorts.
Participants for whom the retinal imaging data required for the planned analyses are unavailable.
Participants whose retinal images are of insufficient quality for reliable image analysis.
Trial population
The study population will consist of patients with inherited retinal degeneration (IRD) and non-IRD control participants identified through participating tertiary ophthalmology and inherited retinal degeneration centers across international study sites. Clinical, demographic and imaging data will be obtained from existing institutional records and imaging databases. Non-IRD myopic and non-myopic control participants will be selected from the same or comparable populations to provide an appropriate reference dataset.
Trial design
Case-control
Retrospective
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Performance of an Artificial Intelligence (AI) algorithm for the diagnosis of Inherited Retinal Degeneration Associated With Biallelic RPE65- mutations using Ultra-Wide field retinal imaging
The primary outcome will be the performance of the artificial intelligence algorithm for the diagnosis of RPE65- associated retinal degeneration using wide-field color/ pseudocolor fundus images acquired with Optos and Clarus and fundus autofluorescence images acquired from Clarus and Heidelberg engineering imaging systems. Performance will be evaluated on an independent held-out test dataset using standard classification metrics, including sensitivity (recall), specificity, precision (positive predictive value), negative predictive value, accuracy, F1 score, and area under the receiver operating characteristic curve (AUROC).
Performance of an Artificial Intelligence (AI) algorithm for the diagnosis of Inherited Retinal Degeneration Associated With RPGR- mutations using Ultra-Wide field retinal imaging
The primary outcome will be the performance of the artificial intelligence algorithm for the diagnosis of RPGR- associated retinal degeneration using wide-field color/ pseudocolor fundus images acquired with Optos and Clarus and fundus autofluorescence images acquired from Clarus and Heidelberg engineering imaging systems. Performance will be evaluated on an independent held-out test dataset using standard classification metrics, including sensitivity (recall), specificity, precision (positive predictive value), negative predictive value, accuracy, F1 score, and area under the receiver operating characteristic curve (AUROC).
Performance of an Artificial Intelligence (AI) algorithm for quantification and longitudinal monitoring of Inherited Retinal Degeneration Associated With Biallelic RPE65- Mutations.
The performance of an AI algorithm will be evaluated for the detection, segmentation, and quantitative assessment of panretinal pathological features (before and after therapy) associated with biallelic RPE65-related retinal degeneration using wide-field color/ pseudocolor fundus images acquired with Optos and Clarus and fundus autofluorescence images acquired from Clarus and Heidelberg engineering imaging systems. Algorithm performance will be assessed using predefined metrics including sensitivity (recall), specificity, precision, negative predictive value, accuracy, F1 score, Dice similarity coefficient, and area under the receiver operating characteristic curve (AUROC), as applicable.
Performance of an Artificial Intelligence (AI) algorithm for quantification and longitudinal monitoring of Inherited Retinal Degeneration Associated With RPGR- Mutations.
The performance of an AI algorithm will be evaluated for the detection, segmentation, and quantitative assessment of panretinal pathological features associated with RPGR-related retinal degeneration using wide-field color/ pseudocolor fundus images acquired with Optos and Clarus and fundus autofluorescence images acquired from Clarus and Heidelberg engineering imaging systems. Algorithm performance will be assessed using predefined metrics including sensitivity (recall), specificity, precision, negative predictive value, accuracy, F1 score, Dice similarity coefficient, and area under the receiver operating characteristic curve (AUROC), as applicable.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
University College, London
Lead sponsor
Moorfields Eye Hospital NHS Foundation Trust
Collaborator
TransMIT GmbH c/o Justus Liebig University Giessen
Collaborator
Massachusetts Eye and Ear Infirmary
Collaborator