About this trial
Ventricular tachycardia (VT) is a life-threatening heart rhythm disorder that frequently occurs in patients with structural heart disease, such as ischemic or non-ischemic cardiomyopathy. In these patients, VT usually arises from re-entrant circuits within or around scar tissue in the heart muscle. Catheter ablation, which uses radiofrequency energy to eliminate the abnormal tissue responsible for VT, is an established treatment. However, its long-term success rate remains modest (about 40-60%), partly because conventional three-dimensional electroanatomical mapping (EAM) relies on voltage measurements that cannot fully reveal the complex three-dimensional scar architecture that drives the arrhythmia.
Cardiac magnetic resonance imaging (MRI) with late gadolinium enhancement (LGE) can visualize myocardial scar in high detail before the procedure. Dedicated software (ADAS-3D) converts these MRI scans into a patient-specific three-dimensional model of the scar, including the "heterogeneous tissue channels" of surviving muscle within the scar that are the likely source of VT. This model can be integrated into the mapping system during the ablation procedure, potentially allowing operators to identify and treat the critical tissue more precisely.
This prospective, multi-center, single-blind, randomized controlled trial is testing whether adding LGE-MRI guidance to conventional electrical mapping improves the outcomes of VT ablation. Adults aged 18 to 75 years with structural heart disease and documented sustained VT will undergo cardiac MRI screening. Those with visible scar (LGE-positive) will be randomly assigned in a 1:1 ratio to one of two groups: ablation guided by LGE-MRI integrated with electroanatomical mapping (experimental group), or ablation guided by electroanatomical mapping alone without image integration (control group, with operators blinded to the MRI findings). Patients without scar on MRI will be followed in a separate observational registry.
All participants will be monitored in hospital for at least 24 hours after the procedure and will attend clinic visits at 3, 6, and 12 months. VT recurrence will be monitored with wearable smart ECG devices (worn for at least 7 days at each follow-up) and, in patients with an implantable cardioverter-defibrillator (ICD), by device interrogation. The main goal of the study is to determine whether MRI-guided ablation reduces the combined risk of VT recurrence, cardiovascular hospitalization, or death during 12 months of follow-up compared with standard ablation. The study also assesses procedure-related complications.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Aged 18 to 75 years;
Diagnosis as SHD (including ICM and NICM);
Documented sustained VT.
Disqualifiers
Contraindications to catheter ablation (e.g., intracardiac thrombus, decompensated heart failure)
Prior ablation therapy for premature ventricular contractions or VT;
History of cardiac surgery;
Stroke or transient ischemic attack (TIA) within the past 6 months;
Trial design
Parallel
Treatments tested in this trial
LGE-MRI-integrated EAM-guided catheter ablation
Procedure/SurgeryRadiofrequency catheter ablation of ventricular tachycardia guided by LGE-MRI (ADAS-3D) image integration with the EnSite X electroanatomical mapping system.
Conventional EAM-guided catheter ablation
Procedure/SurgeryRadiofrequency catheter ablation of ventricular tachycardia guided by electroanatomical mapping alone (EnSite X system), without MRI image integration.
Treatment groups
Trial outcomes
Primary outcomes
Composite of ventricular tachycardia recurrence, cardiovascular hospitalization, or death
VT recurrence is defined as any appropriate ICD therapy (shock or antitachycardia pacing) or documented sustained monomorphic VT lasting more than 30 seconds. Cardiovascular hospitalization is defined as hospital admission after the randomly assigned procedure due to heart failure, procedure-associated complications, or arrhythmic causes.
Secondary outcomes
Ventricular tachycardia recurrence rate at 6 months
Proportion of patients with recurrent VT, defined as any appropriate ICD therapy (shock or antitachycardia pacing) or documented sustained monomorphic VT lasting more than 30 seconds.
Outcomes of the LGE-negative ablation registry cohort compared with the randomized patients
Prespecified comparison of the composite of VT recurrence, cardiovascular hospitalization, or death between the prospective observational registry of LGE-negative patients undergoing ablation and the randomly assigned (LGE-positive) patients.
Incidence of ablation-related complications
Incidence of procedure-related adverse events, including pericardial tamponade, pericardial effusion, cardiac perforation, esophageal fistula, and thromboembolism.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: