About this trial
With the exception of the shoulder, the hip is among the most frequently injured areas in swimmers. Despite this, hip injuries are often overlooked in training and prevention programmes. Such neglect can cause significant damage to muscles, particularly the adductors, and the joint itself, potentially requiring arthroscopic surgery or even leading to secondary injuries in related structures such as the knee. Furthermore, hip strength and range of motion directly affect swimmers' underwater kicking speed. Although hip assessments are common in other sports, like football, for injury prevention and performance analysis-both dynamically and isometrically-isometric testing is particularly recommended due to its higher reproducibility.
Therefore, this study aims to validate a multidirectional isometric hip test in swimmers and examine agonist-antagonist muscle ratios in young advanced swimmers.
A comparative analysis will be conducted on 30 elite swimmers. This will include a descriptive analysis of the group and comparative analyses between breaststroke/non-breaststroke swimmers and between genders. Maximum isometric contractions of both lower limbs will be measured using a Chronojump force sensor (Boscosystem, Barcelona, Spain).
Athletes will stand on a step positioned centrally within a rack or cage, either laterally or frontally depending on the movement assessed (ABD-ADD or flexion-extension, respectively). They will grip the appropriate supports with their hands and perform three maximal efforts of each movement lasting 3 seconds, without compensatory actions (any attempt with compensations will be discounted). There will be a 20-second rest between attempts. All three attempts will be recorded.
To assess measurement reliability, tests will be repeated after 48 hours for subsequent comparison.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Aged between 14 and 18 years.
Swimmers who train at least 15 hours weekly.
Swimmers who have participated in the national championship this season.
Disqualifiers
Swimmers with any current hip or lower limb pathology.
Swimmers who have required hip surgery.
Swimmers who, for any other reason, are unable to complete an isometric maximal strength test.
No ability to perform the Multidirectional Isometric Assessment of the Hip without compensatory movements.
Trial design
Single group
Treatments tested in this trial
Multidirectional Isometric Assessment of the Hip
Diagnostic testParticipants perform isometric tests (flexion, extension, ABD, ADD) to assess isometric hip strength at different basic movements over two sessions. Data is collected to evaluate the reliability and validity of these tests for swimmers.
Treatment groups
Trial outcomes
Primary outcomes
Intraclass Correlation Coefficient (ICC) for Multidirectional Isometric Test.
Assessment of between-day reliability of the Multidirectional Isometric Test using intraclass correlation Coefficients (ICC) for hip flexion, extension, abduction and adduction movements.
Coefficient of Variation (CV) for Multidirectional Isometric Test.
Analysis of the coefficient of variation (CV) to evaluate data dispersion and consistency for Multidirectional Isometric Test.
Minimum Detectable Change (MDC) for Multidirectional Isometric Test.
Calculation of the minimum detectable change (MDC) to identify the smallest significant change in performance beyond measurement error for Multidirectional Isometric Test. (MDC90: Minimal Detectable Change at 90% Confidence; MDC%: Minimal Detectable Change Percentage).
Force Ratios Between for Multidirectional Isometric Test.
Evaluation of the agonist-antagonist strength ratios between hip flexion, extension, abduction and adduction movements.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: