About this trial
One of the most serious complications with leadless pacemaker (LP) implants is right ventricle (RV) perforation. Understanding the accuracy of fluoroscopic guidance of implants compared to transthoracic echocardiograms (TTE) and computed tomography angiography (CTA) of the heart will help guide future implant techniques. We hypothesize that TTE-guided implantation would lead to improved safety and accuracy of leadless pacemaker implants.
The implanter and two independent electrophysiologists will estimate the location of the implant based on standard fluoroscopic views using RV site nomenclature after the procedure. Each participant will then undergo a TTE and have 3 independent assessments of the implant site. Within 48 hours of the implant, a CTA of the heart will then be performed with contrast, which will serve as the gold standard to determine the actual implant site.
The primary endpoint will compare implanting electrophysiologist, fluoroscopy, and TTE predicted location of a new implanted Micra VR or AV2 leadless pacemaker to the implant location found on a gold standard CTA of the heart. The secondary endpoints will compare implant technique (Jugular vs. Femoral) by defining timing of implant procedure, repositioning, and accuracy of predicted implant location. The other secondary endpoints will compare baseline and demographic characteristics (BMI, COPD, LVEF, implant technique) to EKG parameters at final position, fluoroscopy and TTE image quality, acquisition of triangle or Koch and Bachmann area view during TTE.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Male and female patients aged 18-89, inclusive.
All patients undergoing implant of a new Micra VR or AV2 leadless pacemaker.
Disqualifiers
Women who are pregnant or breastfeeding
Existing device implant
Breast or Pectoral Implants
Patients with a GFR less than 45, unless the patient is on dialysis (in which case, may be included)
Trial design
Single group
Treatments tested in this trial
Cardiac Imaging by TTE or CTA
Diagnostic testAfter a standard care pacemaker implantation, participants will undergo two standard care imaging procedures which will be compared.
Treatment groups
Trial outcomes
Primary outcomes
Assess accuracy predicted implant locations to CTA
Compare implanting electrophysiologist-, fluoroscopy-, and TTE-predicted location of a new implanted Micra VR or AV2 leadless pacemaker to the implant location found on a gold standard modality, CTA of the heart. \[measure: location accuracy\]
Secondary outcomes
Implant technique timing
Compare time required for Jugular vs. Femoral implant techniques \[measure: minutes}
Implant technique repositioning
Compare Jugular vs. Femoral implant techniques by defining repositioning attempts \[measure: number of attempts\]
Implant technique prediction accuracy
Compare Jugular vs. Femoral implant techniques by defining the accuracy of predicted implant location \[measure: percentage\]
Baseline characteristics
Compare baseline characteristics (BMI, COPD, LVEF, implant technique) to EKG parameters at final position, fluoroscopy and TTE image quality, acquisition of triangle or Koch and Bachmann area view during TTE \[measure: scale 1-5\]