Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorUniversidade Federal do Paraná

About this trial

This study evaluates the mental workload and user experience associated with a Brain-Computer Interface (BCI) device called Exobots. The Exobots system uses a non-invasive electroencephalography (EEG) headset to detect neural signals and control a robotic glove that assists hand movement. The primary goal is to assess how three different system sensitivity levels (low, medium, high) impact mental effort, usability, and overall user perception. Healthy adult volunteers (students and staff from IFPR and UFPR) will participate in a single experimental session. During the session, they will perform a repeated mental imagery task (imagine hand movement) while the EEG records their brain activity. After each sensitivity block, participants will complete standardized questionnaires (NASA Task Load Index and User Experience Questionnaire) and a semi-structured qualitative interview about their experience. By combining objective neurophysiological data with subjective feedback, this research aims to identify optimal sensitivity thresholds that minimize cognitive strain and maximize user comfort. The findings are expected to provide technical recommendations for designing more adaptive, user-centered BCI systems for future neurorehabilitation applications.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Technical-level students, undergraduate students, graduate students, and staff members, of both sexes, healthy, affiliated with the Federal University of Paraná (UFPR) or the Federal Institute of Paraná (IFPR).

Age 18 years or older.

Disqualifiers

Use of psychoactive medications.

History of epilepsy or other neurological conditions that would preclude the use of the device.

Severe motor limitations that prevent interaction with the device.

Recent traumatic brain injuries.

Trial design

Design model

Single group

Treatments tested in this trial

  • EEG-Based Brain-Computer Interface Device

    Other intervention

    Non-invasive electroencephalography (EEG)-based Brain-Computer Interface (BCI) system consisting of a 6-channel EEG headset and a robotic hand exoskeleton (glove). The device detects motor imagery neural signals associated with imagined hand movements. When the EEG signal is maintained above a predefined sensitivity threshold for three consecutive seconds, the system triggers the robotic glove to passively move the participant's hand. The study evaluates three distinct sensitivity levels (low, medium, high) during individual calibration. The EEG headset uses water-based conductive gel on contact points to ensure signal quality. The device is manufactured by Neurobots and provided for this research.

Treatment groups

30 Participants
are divided into 1 treatment group
Group A: Exobots BCI DeviceExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

EEG Theta/Beta Ratio as a Neurophysiological Marker of Cognitive Load

Change in the theta/beta spectral power ratio derived from 6-channel electroencephalography (EEG) recordings during motor imagery (imagined hand movement) tasks. The theta/beta ratio is a validated neurophysiological indicator of cognitive workload and mental effort. This measure is compared across the three distinct device sensitivity levels (low, medium, high) to assess differences in cognitive demand.

Time frame
Measured continuously during each 10-minute experimental block (blocks 1, 2, and 3) throughout the single 35-minute session.

Secondary outcomes

1

NASA Task Load Index (NASA-TLX) Global Workload Score

Subjective assessment of perceived mental workload using the NASA-TLX questionnaire. The instrument evaluates six dimensions: mental demand, physical demand, temporal demand, performance, effort, and frustration. The global workload score ranges from 0 to 100, with higher scores indicating greater perceived workload.

Time frame
Immediately after each sensitivity block (3 times total) during the experimental session.
2

User Experience Questionnaire (UEQ) Scores

Assessment of user experience using the standardized User Experience Questionnaire (UEQ). The instrument measures six scales: Attractiveness, Perspicuity, Efficiency, Dependability, Stimulation, and Novelty. Each scale ranges from -3 (very negative) to +3 (very positive), with higher scores indicating a more favorable user experience.

Time frame
At the end of the entire experimental session.
3

Qualitative Feedback on BCI Physical Interface and Overall Experience

Thematic content analysis of responses collected through a semi-structured qualitative interview consisting of open-ended questions and visual thematic cards. The analysis captures nuanced perceptions regarding the physical interface (EEG cap and robotic glove), comfort, emotional engagement, usability, and suggestions for device improvement.

Time frame
Immediately following the conclusion of the experimental session.
4

Individual Operational Sensitivity Thresholds

Identification of the optimal sensitivity level (low, medium, or high) for each participant based on the calibration phase and successful device triggering during motor imagery tasks. This measure assesses how individual neural signal characteristics influence the optimal threshold for reliable BCI operation.

Time frame
During the calibration phase and across all three experimental blocks within the session.

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Universidade Federal do Paraná

Lead sponsor

Instituto Federal do Paraná (IFPR)

Collaborator

Universidade Federal do Paraná (UFPR)

Collaborator

Universidade Tecnológica Federal do Paraná (UTFPR)

Collaborator

This trial is not recruiting at the moment. You can still explore other options: