New Interactive Sensor-home-based Hand Training to Improve Dexterity

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-99
SponsorLuzerner Kantonsspital

About this trial

Primary objective of this study is to explore the impact of a 3-week upper limb hand function training in patients with PD, MS or stroke. The benefits on hand function of this training program will be evaluated. The hypothesize is that the 3-week upper limb hand function training improves finger dexterity.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Patients with confirmed PD, according to UK Brain bank Criteria (Hughes et al., 1992) or

MS patients with relapsing-remitting MS (RRMS), secondary-progressive MS (SPMS) or primary progressive MS (PPMS) according to the revised McDonald's criteria or

subacute stroke

written and signed informed consent

Disqualifiers

MoCA <21/30

psychiatric disease

participation on other interventional trials

Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, dementia, etc.

Trial design

Design model

Single group

Treatments tested in this trial

  • smart sensor egg training

    Device

    The portable hand trainer has three principal functionalities: (I) Grasping, (II) Pronosupination, and (III) wrist and finger extension. Different exercises can be done.

Treatment groups

160 Participants
are divided into 1 treatment group
Group A: smart sensor egg trainingExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

hand dexterity

Nine Hole Peg test (9-HPT): The 9-HPT is a standardized, well established, and reliable measure of hand dexterity in patients with PD, MS, or stroke. seconds will be measured.

Time frame
3 weeks

Secondary outcomes

1

fine finger movements

Coin rotation task (CRT): The CRT measures fine coordinated finger movements and is a suitable and valid dexterity test in patients with PD, MS, or stroke. The seconds for 20 halfturns will be measured.

Time frame
3 weeks
2

grip strength

The handheld JAMAR dynamometer measures the grip strength. kg will be measured.

Time frame
3 weeks
3

cognition

Montreal Cognitive Assessment (MOCA): Cognitive screening tool with a scale from 0 - 30 points. A higher score means a better outcome.

Time frame
baseline
4

executive function

Trail Making Tests (TMT) parts A \& B. Results for both TMT A and B are reported as the number of seconds required to complete the task; therefore, higher scores reveal greater impairment.

Time frame
3 weeks

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.