Non-Invasive Hemodynamic Assessment in Cardiogenic Shock

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorA.O.U. Città della Salute e della Scienza

About this trial

Pulmonary artery catheter (PAC) monitoring is the reference standard for hemodynamic assessment in cardiogenic shock (CS), but it is invasive, resource-demanding and not universally available. HD-ASSESS-CS is a prospective, observational, multicenter study that will enroll consecutive adult patients with CS or pre-shock in whom PAC monitoring is clinically indicated. In each patient, a standardized comprehensive transthoracic echocardiography will be performed in close temporal proximity to invasive measurements, at baseline and at repeated time points during hospitalization. The study will assess the agreement between echocardiographic and invasive hemodynamic parameters, develop novel multiparametric echocardiographic indices (strain, Doppler and cardiac time intervals), and explore artificial intelligence models for automated estimation of hemodynamics from echocardiographic images. PAC placement is not performed for research purposes and AI outputs are not used for patient care.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 years or older

Clinical diagnosis of cardiogenic shock or pre-shock

Clinical indication for invasive hemodynamic monitoring with a pulmonary artery catheter according to standard of care

Written informed consent

Disqualifiers

Refusal or inability to provide informed consent

No clinical indication for pulmonary artery catheter monitoring

Trial population

Consecutive adult patients admitted to tertiary cardiac intensive care units with cardiogenic shock or pre-shock and a clinical indication for pulmonary artery catheter monitoring.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Comprehensive transthoracic echocardiography

    Diagnostic test

    Standardized comprehensive echocardiographic hemodynamic assessment performed in close temporal proximity to pulmonary artery catheter measurements, at baseline and at predefined time points during hospitalization. No study-specific therapeutic intervention is performed.

Treatment groups

250 Participants
are divided into 1 treatment group
Group A: Cardiogenic shock or pre-shock with pulmonary artery catheter monitoring1 intervention

Trial outcomes

Primary outcomes

1

Agreement between echocardiographic and invasive (pulmonary artery catheter-derived) hemodynamic parameters

Bias (mean difference) and 95% limits of agreement (Bland-Altman analysis) between echocardiographic estimates and pulmonary artery catheter measurements of stroke volume, cardiac output/index, right atrial pressure, pulmonary capillary wedge pressure, pulmonary artery pressures and vascular resistances.

Time frame
Baseline

Secondary outcomes

1

Agreement in prespecified subgroups

Bias and 95% limits of agreement between echocardiographic and invasive parameters according to shock etiology and severity, presence and type of mechanical circulatory support, cardiac rhythm and image quality.

Time frame
Baseline
2

Concordance of longitudinal hemodynamic changes

Concordance between changes over time in invasive and echocardiographic hemodynamic parameters across serial paired assessments.

Time frame
From baseline up to pulmonary artery catheter removal, an average of 1 week
3

Agreement of echocardiographic estimates of derived hemodynamic parameters

Bias and 95% limits of agreement for cardiac power output, pulmonary artery pulsatility index, right ventricular stroke work index, pulmonary arterial elastance and systemic vascular resistance.

Time frame
Baseline
4

Incremental accuracy of novel echocardiographic indices

Improvement in accuracy (coefficient of determination, mean absolute error, root mean square error, area under the receiver operating characteristic curve for clinical thresholds) of multiparametric indices based on strain, Doppler and cardiac time intervals compared with conventional echocardiographic metrics.

Time frame
Baseline

Other outcomes

1

Accuracy of artificial intelligence models for automated hemodynamic estimation

Accuracy of deep-learning models in estimating hemodynamic parameters from echocardiographic images (mean absolute error, root mean square error, correlation with invasive values, area under the receiver operating characteristic curve for clinically relevant thresholds), using PAC measurements as reference. Models are developed offline and not used for patient care.

Time frame
Through study completion, an average of 3 years

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

A.O.U. Città della Salute e della Scienza

Lead sponsor

IRCCS Ospedale San Raffaele

Collaborator

University of Turin, Italy

Collaborator

This trial is not recruiting at the moment. You can still explore other options: