Elevated intracranial pressure is a common complication of brain injury which means that the pressure within the skull rises above normal levels. The negative impact of increased intracranial pressure (ICP) on the prognosis of patients has been strongly shown in numerous studies and ICP-based treatment is associated with an important reduction of risk of death. Invasive ICP measurement methods are nowadays a standard of care in severe brain injury. The two available ways of measuring ICP require neurosurgical procedure to implant a catheter and probes within the brain and present risks and complications for the patient, such as infections and intracranial bleeding. In addition, invasive recording of ICP requires neurosurgical expertise and intensive care unit (ICU) facilities, limiting the application of ICP measurements to patients of the acute neuro-ICU (neuro-Intensive Care Unit) with acute brain damage requiring close surveillance to prevent further deterioration of neural tissue and disability. Non-invasive ICP monitoring benefits include no risk of complications seen in invasive monitoring, helping in deciding which patient needs invasive ICP monitoring, and providing ongoing long-term measurements of ICP without having to insert a new device every time. Although many non-invasive ICP measurement methods have been explored, to date, none of them have shown clinical success or usefulness. One under-explored window to ICP is the orbital vein, a small blood vessel located near your eye, which we think could provide a direct link to the intracranial pressure. The study device, called the CPMX3 system, is a non-invasive method to measure pressure in a superficial periorbital vein.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Male or female

Age > 18

Equipped with an invasive ICP monitor as part of standard of care

Disqualifiers

Presence of facial and/or skull trauma that could hinder placement of the pneumatic mask or contraindicate ultrasound on the forehead

History of recent cranial surgery or hemicraniectomy

Active bleeding (proven or suspected)

History or known pathological condition or injury linked to the orbital socket influencingvenous outflow (e.g. Grave disease, tumor, inflammation, trauma, glaucoma, etc.)

Trial design

Design model

Single group

Treatments tested in this trial

  • CPMX3

    Device

    CPMX3 periorbital vein pressure measurement

Treatment groups

15 Participants
are divided into 1 treatment group
Group A: CPMX3 MeasurementExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Safety of venous pressure of the isolated periorbital vein measured with the CPMX3 System to estimate ICP, evaluated by incidence of reported adverse events

Time frame
up to 7 days
2

Safety of venous pressure of the isolated periorbital vein measured with the CPMX3 System to estimate ICP, evaluated by incidence of reported Device Deficiencies (DDs)

Time frame
Up to 7 days
3

Safety of venous pressure of the isolated periorbital vein measured with the CPMX3 System to estimate ICP, evaluated by incidence of reported Serious Adverse Device Effects (SADEs)

Time frame
Up to 7 Days
4

Preliminary accuracy of venous pressure of the isolated periorbital vein measured with the CPMX3 System to estimate ICP, measured in mmHg

Preliminary accuracy will be assessed by recording paired measurements of venous occlusion pressure of the periorbital vein when isolated from its surrounding network and invasive ICP measurements from the standard of care invasive ICP monitor in mmHg

Time frame
up to 7 days

Secondary outcomes

1

Feasibility of finding and compressing the target periorbital vein as reported by the investigator using a visual analog scale 0 to 3

As reported by investigator using a visual analog scale score from 0 to 3 (0: not able to visualize the vein, 3: perfectly able to visualize)

Time frame
up to 7 days
2

The tolerability of the non-invasive measurement process, evaluated via a dedicated patient questionnaire on patient comfort

Evaluated by each participant before study termination through a dedicated questionnaire

Time frame
up to 7 days