About this trial
Somatosensory evoked potentials are crucial in determining the physiological changes of potentials in nerve pathways. Although their main function is diagnostic, the investigators have recently been used as a physiological test to determine physioelectric changes in healthy subjects to study applied stimuli, such as laser, pain or electrotherapy.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Healthy people
Optimal cognitive abilities and mentally competent to participate in the study.
In condition to complete the study questionnaires.
Disqualifiers
Focal mononeuropathies in both upper and lower limbs
Peripheral neuropathy.
Patients with implanted functioning pacemakers / defibrillators. Patients with bleeding disorders. Patients being treated with anticoagulants. Patients on antiplatelet therapy.
Present some of the contraindications for a treatment with NESA XSIGNAL®: pacemakers, internal bleeding, do not apply electrodes on skin in bad condition, with ulcerations or wounds, acute febrile processes, acute thrombophlebitis and / or electricity phobia.
Trial design
Single group
Treatments tested in this trial
Non-invasive Neuromodulation
DeviceThe electrodes will be placed with the help of gloves and adapted socks for 1 hour, twice a week, until 10 intervention sessions are completed. In addition, depending on the session, an adhesive electrode will be placed at the level of C7. Characteristics of microcurrents: pulsed monophasic rectangular wave with a pulse of 1.3 s and pause of 300 ms, voltage 3 mV and intensity 0.5 μA.
Treatment groups
Trial outcomes
Primary outcomes
Response speed of the central and peripheral nervous system to a stimulus 1
The Somatosensory Evoked Potentials of both median and ulnar nerves will be evaluated. Neurophysiological tests of the nervous system that functionally assesses the nerve pathways of the central and peripheral nervous system. For its evaluation, distal stimuli are generated in the wrists in the range of 3-4Hz with intensities above the sensitive threshold and below the pain threshold.
Secondary outcomes
Response speed of the central and peripheral nervous system to a stimulus 2
Somatosensory Evoked Potentials of both Posterior Tibial and Peroneal nerves will be evaluated. Neurophysiological tests of the nervous system that functionally assesses the nerve pathways of the central and peripheral nervous system. For its evaluation, distal stimuli are generated in the wrists in the range of 3-4Hz with intensities above the sensitive threshold and below the pain threshold.
Response speed of the central and peripheral nervous system to a stimulus 3
Somatosensory Evoked Potentials of the sensory auricular branch of the vagus nerves will be evaluated. Neurophysiological tests of the nervous system that functionally assesses the nerve pathways of the central and peripheral nervous system. Stimulations and recordings will be carried out only in the left auditory pavilion (since the right, due to the connection with the sinoatrial node of the heart by means of vagus efferences, can cause, according to the reports consulted, alteration of the heart rhythm and presyncope). Stimulations will be performed by means of a needle connected to the stimulator equipment, or in the tragus, by means of atrial surface electrode or auriculotherapy needle dipole.
Response speed to sensitive stimuli in the palms of the hand and sole of the feet
Several simultaneous bilateral recordings after stimuli in the palms of the hand and sole of the feet above the sensory threshold in the limb contralateral to the recording, with a time between stimuli greater than one minute, to avoid habituation of the response. The latency of the first maximum deflection, in millivolts.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: