About this trial
Although breakthroughs in the management of Parkinson's disease (PD) have emerged in recent decades resulting in better control in symptoms, majority of patients with PD are still living with various disabling motor and non-motor symptoms despite they are already receiving the best contemporary medical or surgical treatments available to them. There is obviously a need to develop additional treatment modality to further optimize the control of symptoms and/or slow the disease progression for patients having PD.
Vagus nerve stimulation (VNS), a type of noninvasive brain stimulation is believed to modify brain rhythms by modulating the nucleus of the solitary tract and locus coeruleus and other regions known to play a role in gait. Moreover, VNS may modulate inflammatory pathways and reduce oxidative stress, making it a potential disease modifying treatment approach for neurodegenerative diseases linked to neuroinflammation such as PD
Further study is warranted to explore the efficacy of non-invasive VNS for its effects on gait and other symptoms of PD as well as the anti-inflammatory effects.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Idiopathic PD as defined by the UK Parkinson's Disease Society Brain Bank Diagnostic Criteria
Age 40 - 75 years old
Availability of a caregiver at home
Cantonese speaker
Disqualifiers
Patients with atypical parkinsonism (e.g., multiple system atrophy, progressive supranuclear palsy, dementia with Lewy Bodies)
PD with dementia
PD patients with DBS in-situ
Severe PD with a Hoehn and Yahr staging of 4 or above
Trial design
Parallel
Treatments tested in this trial
cVNS
DeviceThe cVNS emits a low-voltage 5.56 KHz sinusoidal wave electrical signal bursts lasting 0.9 ms via two flat stimulation contact surfaces. (Figure 2) These bursts repeat once every 38 millisecond (ms). Each set of stimulation will be applied for 2 minutes. Stimulation current can be self-adjusted by the subject. This conventional stimulation waveform was approved by the US FDA for the treatment of migraines.
eVNS
DeviceThe eVNS emits the company-proprietary low-voltage of 3\~8 KHz sine-variant smooth-transition wave electrical signal bursts lasting near 0.9 ms via two flat stimulation contact surfaces. These bursts repeat once in intervals of approximately 40 ms. A potential benefit of this waveform is that it can produce less unpleasant skin sensations at a given current intensity and this may enhance the subject to tolerate higher current intensity than that of the conventional stimulation.
sVNS
DeviceThe sVNS delivers mechanical motor vibrations to provide a similar perceptible stimulation feeling to the skin. No electrical stimulations are delivered. The device that delivers the sham stimulation is identical in appearance, weight, and user interface. A button to adjust "stimulation current" is also available in the sham device so as to allow the subject/caregiver to adjust the "stimulation current"
Treatment groups
Trial outcomes
Primary outcomes
Change of gait
Timed UP and Go test: Participant sits back in a standard armchair with their back against the chair and hands resting on the armrests. Regular footwear and usual walking aids (like a cane or walker) are used. On the word "Go", the person stands up, walks a distance of 3 meters (10 feet) to a marked line or cone at a normal, safe pace, turns around, walks back to the chair, and sits down again. A stopwatch starts the moment the word "Go" is spoken and stops the moment the person's buttocks touch the seat. The results in second will be interpret to assist mobility and risk of falling. The longer the time, the high risk of fall
Severity and progression of Parkinson's disease
Using Unified Parkinson's Disease Rating Scale to motor and non-motor symptoms. Score from 0 to 4. 0 is normal while 4 is severe/marked impairment
Quantitative Gait Assessment
Using an app to track the mobility of participants in a 20 sec walking
Cognitive status
Using Hong Kong Montreal Cognitive Assessment to evaluate the cognitive status. score from 0-30. The lower the score, the more cognitive impaired.
Secondary outcomes
Change of blood pressure
Safety measures- record of adverse event and serious adverse event
To investigate any possibility and relativity of AE and SAE with the treatment
Electrocardiogram
To investigate any possibility and relativity of the change of ECG with the treatment
Other outcomes
Blood-based biomarkers
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: