About this trial
The COSMO study aims to investigate whether a noninvasive test based on otoacoustic emissions, which are sounds produced by the inner ear, can provide useful information about changes in intracranial pressure in people with glaucoma and healthy individuals.
Glaucoma is an eye disease that can damage the optic nerve and cause vision loss. Researchers believe that the relationship between pressure inside the eye and pressure inside the skull may play a role in glaucoma.
This study will compare measurements of distortion product otoacoustic emissions (DPOAEs) between patients with glaucoma and healthy participants. Researchers will assess how reproducible these measurements are and how they change with different body positions and changes in intraocular pressure.
Participants will undergo eye examinations and noninvasive ear measurements while assuming different body positions.
The results may help researchers better understand the relationship between intracranial pressure, intraocular pressure, and glaucoma, and evaluate the potential usefulness of otoacoustic emissions as a noninvasive assessment method.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Age between 50 and 70 years.
Central corneal thickness between 500 and 600 µm.
Patent ear canal at otoscopy.
Written informed consent freely provided before the start of any study procedures.
Disqualifiers
History of inner or middle ear disease.
History of cerebral diseases that may increase intracranial pressure (ICP), including neoplastic, ischemic, toxic, or infectious causes of cerebral edema, hydrocephalus, obstruction of major venous sinuses, vascular malformations, or idiopathic intracranial hypertension.
Systemic treatment with medications known to affect ICP, including corticosteroids, nitroprusside, nitroglycerin, hydralazine, nicardipine, topiramate, and loop diuretics (e.g., furosemide).
Non-recordable distortion product otoacoustic emissions (DPOAEs).
Trial design
Parallel
Treatments tested in this trial
Titan System for DPOAE Measurement
DeviceNoninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark). DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence. Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz. In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability.
Treatment groups
Trial outcomes
Primary outcomes
Repeatability of Distortion Product Otoacoustic Emission (DPOAE) Phase Measurements
Assessment of the test-retest repeatability of distortion product otoacoustic emission (DPOAE) phase measurements in glaucoma patients and healthy subjects. DPOAE phase will be measured repeatedly in the sitting position (90°), with removal and reinsertion of the ear probe between measurements. Repeatability will be quantified as the standard deviation of differences between repeated measurements, expressed in degrees of phase.
Secondary outcomes
Differences in DPOAE Phase Changes and Intraocular Pressure Changes Between Study Groups
Comparison of distortion product otoacoustic emission (DPOAE) phase changes, expressed in degrees and averaged over three octave bands (0.5-1, 1-2, and 2-4 kHz), and mean changes in intraocular pressure (ΔIOP), expressed in mmHg, between glaucoma patients and healthy subjects across different body positions (90°, 135°, 180°, and 0°).
Association Between DPOAE Phase Changes, Intraocular Pressure Changes, and Corneal Parameters
Assessment of the relationship between distortion product otoacoustic emission (DPOAE) phase changes (degrees) and intraocular pressure changes (ΔIOP, mmHg) across different body positions, considering central corneal thickness (µm) and corneal hysteresis (mmHg). Associations will be evaluated using Pearson or Spearman correlation coefficients and mixed-effects models.