Normal Reference Range for Neonatal Echocardiography

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age1-28
SponsorChildren's Hospital of Chongqing Medical University

About this trial

Echocardiography is the main method of bedside examination of neonatal cardiac morphology, which can timely diagnose congenital heart disease and quantitatively assess its severity, but the diagnosis and evaluation process depends on the normal range of neonatal echocardiography.At present, there have been normal reference standards for echocardiography in children and adults at home and abroad, but there is no uniform standard for echocardiographic parameters in newborns, especially premature infants.This study intends to carry out a national multicenter, prospective, observational study to establish the reference range of echocardiography at different time periods after birth in newborns, and stratified according to gestational age, birth weight and gender, to conduct a more accurate hemodynamic assessment of clinically critically ill newborns and guide the treatment of critically ill newborns in real time.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Outpatient or inpatient neonate

Gestational age > 30weeks and birthweight > 1250 grams

Appropriate for gestational age

Without perinatal asphyxia

Disqualifiers

specialist cardiac ultrasound suggests congenital heart disease;

PDA with hemodynamic abnormalities, defined as: PDA > 1.5 mm (left-to-right shunt) and left atrial diameter/aortic root > 1.5 or the need for the use of inotropes;

invasive mechanical ventilation therapy,

non-invasive mechanical ventilation with FiO2 >0.3

Trial population

healthy neonates and preterm Infants

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Other intervention

    Neonatal bedside echocardiography was performed by a trained neonatologist or sonographer

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Changes in left atrial anteroposterior diameter with increasing age

The Left atrial systolic anteroposterior diameter was measured by M-mode ultrasound through the aortic root in the long axis of the parasternal left ventricle

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)
2

Changes in interventricular septum thickness with increasing age

The Interventricular septal thickness was measured by left ventricular M-mode ultrasound in the long axis of the parasternal left ventricle

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)
3

Changes in left ventricular posterior wall thickness at end diastole with increasing age

The left ventricular posterior wall thickness at end diastole was measured by left ventricular M-mode ultrasound in the long axis of the parasternal left ventricle

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)
4

Changes in left ventricular end diastolic diameter with increasing age

The left ventricular end diastolic diameter was measured by left ventricular M-mode ultrasound in the long axis of the parasternal left ventricle

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)

Secondary outcomes

1

Changes in left ventricular outflow tract diameter with increasing age

In the standard parasternal long-axis view, images were frozen when the aortic valve was completely opened during systole, and the distance between the anterior and posterior aortic walls at the level of aortic root attachment was measured with an electronic cursor to obtain the left ventricular outflow tract diameter

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)
2

Changes in main pulmonary artery diameter with increasing age

In the parasternal cardiac base short-axis view, the left and right pulmonary arteries were exposed at the same time, and the diameter of the main pulmonary artery was measured

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)
3

Changes in Inferior vena cava diameter with increasing age

Inferior vena cava diameter was measured by M-mode ultrasound in the subxiphoid long-axis plane by transthoracic ultrasound

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)
4

Changes in Simpson 's method for measuring ejection fraction with increasing age

Through the apical four-chamber view or apical two-chamber view, for the tracing of diastolic and systolic endocardium, divide the heart into several (generally 20) cylinders, calculate the volume and add them to obtain the left ventricular end-diastolic and end-systolic volumes, and then calculate the ejection fraction

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)

Other outcomes

1

Changes in Aortic Velocity Time Integral(VTI)with increasing age

In the apical five-chamber view, select the color Doppler mode to display the aortic blood flow signal and direction, place the sampling volume below the arterial orifice, adjust the blood flow direction as parallel as possible to the sampling line through the left and right swing probe, and select the pulsed Doppler mode (PW), then the velocity time integral (VTI) image of aortic blood flow can be obtained. Trace the aortic velocity-time integral image and calculate the VTI value in cm by computer or plotter. Select 3-5 consecutive VTI images within the same respiratory cycle for measurement and average to reduce the impact of the respiratory cycle

Time frame
5 time points (1 day, 3 days, 7 days, 14 days and 28 days after birth)

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Children's Hospital of Chongqing Medical University

Lead sponsor

Shanxi Provincial Maternity and Children's Hospital

Collaborator

Inner Mongolia Maternal and Child Health Care Hospital

Collaborator

Maternal and Child Health Hospital of Guangxi Zhuang Autonomous Region

Collaborator

Ningxia Medical University

Collaborator