About this trial
Heart failure (HF) is a major cardiovascular disease with high readmission and mortality rate. A wearable device that could remotely monitor and detect the worsening HF early before the symptoms appear will help reduce HF readmissions effectively. The purpose of the current study is to examine the efficiency of a novel wearable device based on flexible strain sensor comparing to the clinical 'gold standard,' and then transform it into a clinical application.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Diagnosis of HF ≥ 3 months
Diagnosis of NYHA Class III HF
Subjects with age ≥ 18 years
At least 1 HF hospitalization within 12 months prior to enrollment
Disqualifiers
Subjects unable to cooperate to complete the trial.
Subjects with severe arrhythmia.
Subjects with cardiac shock.
Subjects with acute myocardial infarction.
Trial design
Parallel
Treatments tested in this trial
novel wearable device
DevicePatients with a novel wearable device for monitoring and uploading data daily to collect monitoring data such as jugular vein pressure and exercise steps after discharge.
Treatment groups
Trial outcomes
Primary outcomes
Rate of Hospital Readmissions for Heart Failure
Total hospitalizations for heart failure will be monitored via follow-up.
Secondary outcomes
Concordance of the Jugular Vein Pressure with the RHC Measurement
Accuracy of jugular vein pressure measurements by the novel wearable device compared to right heart catheterization.
Change From Baseline N-terminal Pro-brain Natriuretic Peptide(NT-proBNP) or Brain Natriuretic Peptide(BNP)
Change from baseline to 6 months in N-terminal pro-brain natriuretic peptide (NT-proBNP) or Brain Natriuretic Peptide(BNP). NT-proBNP/BNP level will be measured using commercial kits system during the follow-up period. Change from baseline was defined as the value of NT-proBNP/BNP at 6 months minus the baseline value. Baseline value was defined as the mean of all available measurements from the screening visit.
Change in Exercise Capacity as Measured by the 6-Minutes-Walking-Test (6MWT) Distance.
Change from baseline to 6 months in exercise capacity as measured by the distance walked in 6 minutes in standardised conditions.
Compliance Percentage of Patients
Patient adherence to daily measurement and transmission of sensor readings will be recorded.
Other outcomes
Subjects Included the Endpoint of Cardiovascular Mortality
Rate of cardiovascular mortality will be monitored via follow-up.
Subjects Included the Endpoint of all-cause Mortality
Rate of all-cause mortality will be monitored via follow-up.