About this trial
Optical Coherence Tomography (OCT) machines are non-contact instruments that can measure the depth of scars and other causes of cloudiness in the front of the cornea. The purpose of this study is to determine whether OCT-guided settings for the lasers used for removal of corneal scars and other partial-thickness corneal defects result in improved vision in patients receiving these procedures.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients with vision primarily limited by superficial opacities and irregularities that could be removed by PTK while leaving at least 250 µm.
Disqualifiers
Inability to give informed consent
Inability to maintain stable fixation for OCT imaging
Inability to commit to required visits to complete the study
Deep corneal opacities and irregularities
Trial design
Single group
Treatments tested in this trial
OCT-guided laser phototherapeutic keratectomy
DrugPreoperative measurements from the OCT are used to assist the calculation in deciding the laser depth settings for removal of anterior corneal opacities and defects in the phototherapeutic PTK procedure. The surgeon uses the OCT data to plan a range of treatment parameters to remove most of the opacity while preserving at least 250 microns of residual corneal stroma.
Treatment groups
Trial outcomes
Primary outcomes
Improvement in best spectacle-corrected visual acuity (BSCVA) after PTK
The primary goal of the trial is to determine the efficacy of the OCT-guided PTK treatment of corneal opacities. During the course of the trial, we will compare the predictive accuracy of the original OCT-guided PTK planning system to the OCT topography-guided system. BSCVA will be measured in typical Snellen acuity notation as 20/xx (feet)
Secondary outcomes
Improvement in uncorrected visual acuity (UCVA), refractive error, and higher order aberrations
A second goal is to develop a more sophisticated OCT guidance system incorporating OCT topography of anterior and posterior corneal surfaces and to develop a mathematical model that relates epithelial thickness variation to corneal mean curvature. During the course of the trial, we will compare the predictive accuracy of the original OCT-guided PTK planning system to the OCT topography-guided system. UCVA will be measured in typical Snellen acuity notation as 20/xx (feet)
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Oregon Health and Science University
Lead sponsor
National Eye Institute (NEI)
Collaborator