About this trial
This is a prospective, randomized crossover study. The objective of the study is to determine if a pacing rate of 80 beats per minute (bpm) improves exercise tolerance during the 6-minute walk test. The investigators will randomly assign half of the participants to a starting rate of 60 bpm and then switch them to a rate of 80 bpm for 3 months, and vice versa.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older
History of persistent or permanent atrial fibrillation
Implantation of CRT or conduction system pacing in prior 3 months to 5 years of study start
History of intrinsic AVN block or have undergone AVN ablation in prior 3 months to 5 years of study start
Disqualifiers
LVEF <50%
Wide QRS (greater than 150ms)
Isolated RV pacing
Severe valvular disease
Trial design
Crossover
Treatments tested in this trial
Pacing rate of 80 bpm
DevicePacing rate of 80 bpm
Pacing rate of 60 bpm
DevicePacing rate of 60 bpm
Treatment groups
Trial outcomes
Primary outcomes
Exercise tolerance as measured by the Six-Minute Walk Test
Exercise tolerance as measured by the Six-Minute Walk Test
Secondary outcomes
Quality of life as measured by the Kansas City Cardiomyopathy Questionnaire
Quality of life as measured by the Kansas City Cardiomyopathy Questionnaire
Function as measured by the International Physical Activity Questionnaire
Function as measured by the International Physical Activity Questionnaire
Change in B-type natriuretic peptide (BNP)
Change in B-type natriuretic peptide (BNP)
Change in creatinine
Change in creatinine
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Medstar Health Research Institute
Lead sponsor
Medtronic
Collaborator