About this trial
The current study intends to collect data from Oura Ring time-locked to ground truth medical sleep diagnostic gold-standard polysomnography (PSG) for product research and development, investigational algorithm validation, and scientific dissemination.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Ages 18-85 y
Body mass index (BMI) <30 kg/m2
Self-reported habitual sleep duration of 6-9 hours
Willing and able to comply with the study requirements
Disqualifiers
High risk for mild-to-severe sleep apnea
Individuals with pacemakers
Non-English speakers
Individuals who are unwilling or unable to provide informed consent or comply with study procedures
Trial population
The study population will be composed of adults in the general population in the St. Louis area, including patients from the clinic database and general community.
Trial design
Case-control
Cross-sectional
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Sleep staging performance (co-primary endpoint)
Agreement between Oura Ring sleep stage output and adjudicated PSG sleep stage scoring across the overnight in-laboratory recording (quantified by overall accuracy, Cohen's kappa, and class-specific sensitivity, specificity, positive predictive value, and F1 score for Wake, REM, and NREM sleep).
Signal quality performance (co-primary endpoint)
Signal-to-noise ratio for overnight SpO2 signal quality.
Secondary outcomes
Respiratory event detection performance - apnea events
Event-level detection of PSG-scored apnea events by Oura Ring, quantified by sensitivity, positive predictive value, false positive rate per hour, and F1 score.
Respiratory event detection performance - hypopnea events
Event-level detection of PSG-scored hypopnea events by Oura Ring, quantified by sensitivity, positive predictive value, false positive rate per hour, and F1 score.
Respiratory event detection performance - oxygen desaturation events
Event-level detection of PSG-scored oxygen desaturation events by Oura Ring, quantified by sensitivity, positive predictive value, false positive rate per hour, and F1 score.
Overnight SpO2 agreement
Agreement between Oura Ring overnight oxygen saturation estimates and PSG reference SpO2 measurements over matched overnight intervals, which may be quantified by mean bias, mean absolute error, root mean squared error, correlation, and Bland-Altman limits of agreement.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Ouraring Inc.
Lead sponsor
Clayton Sleep Institute, LLC
Collaborator